Page 1
Operations & Service Manual FSH-6 Hood ISO 9001‐2015 Registered • Committed to Quality 2750 Gunter Park Drive West • Montgomery, AL 36109 USA Toll Free: 800.554.4537 Other: 334.272.1457 (USA & Canada Only) Fax: 334.239.4117 • Website: www.gfse.com • Email: services@gfse.com...
Page 3
• During the Limited Warranty period, Giles will replace or recondition, at its factory, any part or parts of this unit which Giles inspectors judge defective, provided the unit has been properly installed, subjected to nor‐...
The information contained in this manual has been prepared to describe the proper procedures for safely installing, operating and maintaining Giles Food Service Equipment. Throughout the manual, safety precautions are identified by a hazard alert symbol and key words such as DANGER, WARNING or CAUTION.
Model: FSH-6 Safety Specific Safety Precautions: For your safety, please observe the following precautions when operating or servicing this GILES food service equipment. Adhering to the following important safety information will help to prevent personal injury and/or damage to the equipment.
Page 9
Safety Model: FSH-6 Specific Safety Precautions: • Exercise care when removing wooden crate framework and the unit from shipping pallet. The hood is very heavy; extreme precaution must be exercised when handling and assembling the hood’s stand and when lifting and mounting hood onto the stand.
Page 10
Comply with all appropriate state and/or local heath regulations regarding cleaning and sanitation of any foodservice equipment. ▪ To clean difficult surface areas, having excessive build‐up of grease residue, GILES recommends using a mild, biodegradable, non‐toxic degreasing cleaner such as Simple Green® Crystal Foaming Spray Cleaner/Degreaser. ▪...
THANK YOU for purchasing the Giles Model FSH‐6 Ventless Recirculating Hood w/72” Floor Stand, manufactured by Giles Enterprises, Inc., Montgomery, Alabama (USA), hereafter referred to as "GILES". Giles ventless technology is the result of extensive engineering, research and development. Every unit is thoroughly inspected and tested prior to shipment to ensure it operates flawlessly after installation.
Location • DO NOT ALTER, ADD ATTACHMENTS OR OTHERWISE MODIFY THIS EQUIPMENT. • Failure to comply with installation requirements as specified by the Giles Hood Approval Letter will void the factory warranty. 1. A minimum clearance of 14” (355.6 mm) must be maintained between the top of the hood exhaust outlet and ceiling, or other overhead obstruction.
Installation Model: FSH-6 2.02 Unpacking IMPORTANT NOTE!! If there is evidence of damage to the palletized unit, or any of the accompanying items, immediately and thoroughly inspect the unit and all components. Notify the freight company of all damages. Generally, it is the responsibility of the customer to file and negotiate freight damage claims with the carrier.
Page 16
Model: FSH-6 Installation 2.03 Stand & Hood Assembly - continued TRIM CAP TRIM CAP Install upper back panel. TABS ON CHANNELS SHOULD FIT INTO SLOTS ALONG BOTTOM EDGE OF STAND SIDES. ADJUST LEGS TO LEVEL HOOD. Use extreme care when mounting hood onto stand, or when moving...
Installation Model: FSH-6 2.04 Cooking Appliance Limitations & Clearances The diagrams in this section depict ceiling suspended hoods over various appliances. The side clearance minimum dimensions shown in these illustrations will not apply to current free‐standing hood versions. The entire width of the stand skirt is usable for cooking appliances.
Installation Model: FSH-6 2.05 Electrical Specifications - Hood ONLY • Food service equipment must be properly grounded in accordance with local code, or in the absence of local code, with the National Electrical Code, ANSI/NFPA 70. Improper grounding may result in electrical shock to users.
Model: FSH-6 Installation 2.05.2 Routing Power Conduit & Wiring This diagram shows a typical conduit and wiring setup for connecting hood and appliance power. See Section 2.05.3, Hood & Appliance Interlock Diagram for details on setting up the interlock circuit for the under‐Hood appliance.
2.06 Fire Suppression System Installation Giles Ventless Hoods must be protected by the Ansul® R‐102 Restaurant Fire Suppression System in accordance with the hood listing. Procurement, field installation, set‐up, charging, testing and certification of the system is the responsibility of the customer (NOT included with hood). System must be provided and installed by an authorized Ansul®...
Overview Model: FSH-6 Overview This section provides a brief overview of the hood’s components, functions, and accessories. Please review carefully before proceeding. Hood Exhaust Duct Left Filter Right Filter Chamber Chamber Section 3.02 Section 3.02 Control Panel Section 3.01. Hood Stand...
Page 29
Overview Model: FSH-6 3.01 Control Panel Item Description Function Light Switch Controls under‐hood lighting. Press and momentarily hold the top [START] portion of switch to start hood and provide power to appliances underneath. Release Power Switch and switch remains in the [ON] position (center). To turn hood OFF PUSH‐TO‐START...
Page 31
Overview Model: FSH-6 3.02 Filter Chamber & Exhaust Item Description Function Provides access to filter chamber & the filters (pre‐filter, E.A.C. & Hood Filter Door (2) charcoal). Both Doors must be closed and latched before the hood will operate. The first stage of ventless air cleaning system. Stainless steel filters Baffle Filter (2) capture largest grease particulate.
Model: FSH-6 Overview 3.03 Accessory Items Included w/Hood Part Description/Part Number Function Baffle Filter (2) Captures largest grease P/N 42300 particulate in cooking vapors. Removes additional grease‐laden Pre‐Filter (2) vapor and moisture from the air. P/N 91707 Single‐use only, disposable, must be replaced.
Page 33
(2) Sample Cans cleaning EAC collector cell. Foaming Crystal Sample can of the GILES Cleaner/Degreaser recommended collector cell P/N 41510 cleaner. 12‐count Case It is readily available from Giles NSF approved and on‐line distributors, as well as many nationwide retail outlets.
Operation & Filter Maintenance Model: FSH-6 Operation & Filter Maintenance 4.01 Starting the Hood Be sure that all filters are in place and access doors are closed and latched securely before attempting to operate the unit. NOTE: Hood will NOT power‐up if either Filter Door is open, or ajar.
Model: FSH-6 Operation & Filter Maintenance 4.02.2 Baffle Filter Removal ① Turn OFF power. Baffle filters are located on under‐side of hood, directly above the appliances. ② ④ ③...
Operation & Filter Maintenance Model: FSH-6 4.02.3 Baffle Filter Installation ② ① Front View Position filters w/ ③ baffles in a vertical position Switch arm must be actuated by the filter as shown...
Model: FSH-6 Operation & Filter Maintenance 4.02.4 Pre-Filter Removal ① Turn OFF power. Pre‐filters are located inside the filter chamber in the outermost position on each side. Pre‐Filters Door open ② Front View...
Operation & Filter Maintenance Model: FSH-6 4.02.5 Pre-Filter Installation Pre‐Filter Paper side (to outside) Paper side (to outside) Pre‐Filter Door open Metal mesh side (facing toward middle) Switch Roller must be actuated by the Pre‐filter frame when installed. Front View...
Model: FSH-6 Operation & Filter Maintenance 4.02.6 E.A.C. Collector Cell Removal ① Turn OFF power. Collector cells are located inside the filter chamber in the middle position on each side. Door open Left E.A.C. Cell Right E.A.C. Cell ② Folding handle,...
Model: FSH-6 Operation & Filter Maintenance 4.02.8 Charcoal Filter Removal ① Turn OFF power. Charcoal filters are located inside the filter chamber in the innermost position on each side. Charcoal Filter Door open ② Front View...
Operation & Filter Maintenance Model: FSH-6 4.02.9 Charcoal Filter Installation Charcoal Filter Door open Blue fiber‐fill side faces middle Front View Roller of switch must be actuated by charcoal filter frame when installed. Close Door...
Model: FSH-6 Operation & Filter Maintenance 4.03 Hood Filter Alarms 4.03.1 Baffle, Pre-Filter or Charcoal Filter Missing If a Baffle Filter, Pre‐Filter, or Charcoal Filter is not in place, or possibly not positioned correctly, the red [FILTER MISSING] light will turn ON. Power to appliances under the hood is turned OFF until the condition is corrected. No audible alarm will sound.
Operation & Filter Maintenance Model: FSH-6 4.03.3 E.A.C. Filter Status & Alarm Two LED indicator light clusters on the control panel show the operational status of the Electronic Air Cleaner (EAC) filter system for each side of the hood. [ON] Indicates that the EAC collector cell is installed, powered and operating.
A complimentary sample is supplied with new equipment. It can be ordered from Giles, item #41510 (12‐count case). When used as directed, a case of cleaner should approximately be a 4 to 5 week supply, depending on equipment model.
Page 47
IMPORTANT! ONLY Simple Green® Crystal Foaming Cleaner/Degreaser is recommended by GILES for cleaning EAC cells in this manner. Other spray cleaners can contain corrosive ingredients that may damage the metal components of the cell, causing it to fail or not perform properly. Such damages are not covered by the factory warranty.
Model: FSH-6 Operation & Filter Maintenance 4.04.2 E.A.C. Collector Cell Cleaning - continued B. Alternate Cleaning Method - Soaking The factory‐recommended product to use for cleaning EAC cells in this manner is Simple Green® Pro‐HD. It is a readily available, biodegradable, non‐toxic degreasing cleaner that is safe for use on aluminum. It performs well to clean the cell when diluted at a 1:12 ratio (e.g.
Typically, pre‐filters should be replaced weekly (see Sections 4.02.4 & 4.02.5). They CANNOT be cleaned and are not intended for long‐term use. Use GILES replacement Item No. 91707. Write the replacement date on new filter. IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
CANNOT be cleaned and reused. Typical replacement cycle is every 30 to 40 days, depending on usage. Use GILES replacement Item No. 32056. Write the replacement date on new filter. IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
Use the Maintenance & Service Log to record completion of the test. If problems are detected, contact GILES or an authorized service provider. NOTE: Anytime a filter access door is opened and closed, the hood must be restarted with the power switch (press & momentarily hold the top of switch).
Model: FSH-6 Hood Cleaning & Maintenance 5.02 Quarterly Hood Cleaning DO NOT wash down Hood with water from a spray hose. DO NOT steam clean or use any type pressure washing equipment. DO NOT use products containing chlorine or other caustic chemicals.
Hood Cleaning & Maintenance Model: FSH-6 5.03.1 Semi-Annual (6-Mo) Fire Suppression System Inspection & Maintenance Service and inspection of the fire suppression system must be performed by a qualified Ansul® Distributor/Dealer. As a minimum, field inspection of the fire suppression system must be conducted semi‐annually (every 6 months) and shall consist of the following: •...
Model: FSH-6 Model: FSH-6 Troubleshooting This section describes basic troubleshooting procedures for Ventles Recirculating Hoods. Generally, troubleshooting and/or repairs should only be performed by trained and qualified service technicians. Troubleshooting by users should be limited to issues and/or activities that are operational or procedural in nature.
Page 56
Model: FSH-6 Troubleshooting Problem Probable Cause Corrective Action Under‐hood appliances will not a. A baffle filter is missing or not Install filter / check positioning. power‐up: properly installed • [HO light ON OD POWERED] b. A charcoal or pre‐filter is missing Install filter / check positioning.
Website: Email: Our goal at Giles is to provide the highest possible quality of service and assistance. To help us accomplish this, please have the following information readily available when calling, along with a brief description of the problem being experienced. Please record the unit information in the table below for quick reference.
Model: FSH-6 Parts List 7.03 Hood Front - Opened * Inside Chamber, Not Shown...
Page 61
Parts List Model: FSH-6 7.03 Parts List for Hood Front ITEM PART NO. DESCRIPTION 91707 PRE‐FILTER, ASSEMBLY, 12 X 20 X 2 31843 DRIP PAN, E.A.C. FILTER 20521 FILTER, EAC 12 X 20, LEFT SIDE ONLY 32056 CHARCOAL FILTER, ASSEMBLY...
Model: FSH-6 Parts List 7.04 Under-Hood Filters & Lights * Not shown...
Page 63
Parts List Model: FSH-6 7.04 Parts List for Under-Hood ITEM PART NO. DESCRIPTION 42300 BAFFLE FILTER, S/S, 20 X 20 32776 DRIP CUP 32102 BAFFLE FILTER SWITCH ASSY. 40625 LIGHT FIXTURE 20395 FLUORESCENT BULB, COATED...
Model: FSH-6 Parts List 7.05 Doors & Front Panel [Ceiling Suspended Model] NOTE: Legs are welded to Stand Sides; cannot be replaced. * Not shown...
Page 65
Parts List Model: FSH-6 7.05 Parts List for Doors & Front Panel [Ceiling Suspended Model] ITEM PART NO. DESCRIPTION 42827 DOOR LATCH 33637 ACCESS DOOR ASSY, LEFT 46162 FIRE DAMPER 33205 FAN COVER 95051 SCREEN, FIRE DAMPER 33253 ACCESS DOOR ASSY, RIGHT 91945 SKIRT, FSH‐6, 8”, UNIVERSAL...
Page 66
2750 Gunter Park Drive West • Montgomery, Al 36109 USA Phone: 334.272.1457 • Toll Free: 800.554.4537 • FAX: 334.239.4117 • www.gfse.com (USA & Canada Only) Form No. 64898 (Rel. Date: Jul.1999, Rev. Date: Aug.2020, Rev. L)
Need help?
Do you have a question about the FSH-6 and is the answer not in the manual?
Questions and answers