Page 1
Operations & Service Manual OVH-10-C Giles Enterprises, Inc. An ISO 9001-2008 Registered Company • Committed to Quality 2750 Gunter Park Drive West • Montgomery, AL 36109 USA Phone: 334.272.1457 • Fax: 334.239.4117 • Website: www.gfse.com Toll Free: 800.554.4537 ( USA & Canada Only...
Page 3
Giles Enterprises, Inc., representative. • Giles Enterprises, Inc. reserves the right to change or improve its equipment and parts in any way without obligation to alter such equipment or parts previously manufactured.
The instructions contained in this manual have been prepared to aid you in learning the proper procedures for installing and servicing the OVH-10-C Counter-Top Hood. Throughout this manual, safety precautions are identified through the use of safety alert symbols and three key words: DANGER, WARNING and CAUTION.
Model: OVH-10-C Safety Specific Safety Precautions For your safety, please observe the following precautions when operating or servicing the OVH-10-C Ventless Hood. Read the following important safety information to avoid personal injury and/or damage to the equipment or property. DANGER •...
Page 9
Safety Model: OVH-10-C CAUTION • Maintain a minimum clearance of 18” (457.2mm) between the hood’s exhaust outlet and the ceiling, or other overhead obstruction. • Exercise care when lifting or moving the unit. See Section 1-4.4, Hood Weights. • Exercise care when removing the unit from the shipping skid.
Page 10
NOTE: • Giles’ responsibility for the damage to the unit ends once the freight shipment is loaded onto the carri- er’s truck. Upon delivery, if the palletized unit showed any signs of damage, the entire load, including the supplied accessories, should have been inspected immediately and any damage to the equipment should have been promptly reported to the freight company.
Thank You! for purchasing the OVH-10-C Ventless Hood System manufactured by Giles Enterprises, Inc., Montgomery, Alabama, USA. The OVH-10-C is a Limited Type-1 Hood designed specifically for use on counter-top spaces and is listed for use with a variety of small commercial appliances ... Toasters, Conveyor Ovens, Ovens and Rotisseries.
Installation 2. Installation This section summarizes the procedures necessary to install your new OVH-10-C Countertop Hood. Before installing and attempting to operate, please read the contents of this manual thoroughly. Following these procedures will help ensure safe and proper installation.
2. The OVH-10-C Hood model is designed to sit atop a counter space. Ensure that the intended site is structurally sound and capable of supporting the hood’s weight plus that of the appliance(s) to be...
Installation Model: Installation 2-04. Electrical Requirements WARNING • Consult a qualified electrician to ensure that all electrical specifications have been met and that the unit is properly grounded. • Improper installation, adjustment, alteration, service or maintenance could result in serious injury or even death, damage to equipment or property, and void the warranty.
Model: OVH-10-C Model: OVH-10-C 2-04.1. Electrical Connections • qualified electrician or technician. All electrical installation should be performed by a • Improper installation or poor work practices could result in serious injury or even death, damage to equipment or property, and void the warranty.
Model: OVH-10-C Model: OVH-10-C 2-04.2.2 Electrical Connection, 380-480V Applance Power Separate from 208-240V Hood Power USE LIQUID- TIGHT CONDUIT AND FITTINGS 208-240V HOOD POWER 380-480V APPLIANCE POWER...
Installation Model: Installation 2-04.2.3 Electrical Connection, 120V to 480V Appliance Power Separate from 208-240V Hood Power w/Remote Shunt Trip Device 120V to 480V APPLIANCE POWER SEPARATE FROM 208-240 V HOOD POWER (USING REMOTE SHUNT TRIP CONTACTOR SUPPLIED BY LICENSED ELECTRICIAN). Contactor must be a UL Listed, definite purpose, AC resistive, air heating type, suitable for the appliance load.
Installation Model: OVH-10-C 2-05. Air Baffle Installation To prevent damage to the components and unit during shipment, the Air Baffle is not factory-installed. This part must be installed prior to operation for proper performance. No tools are required, refer to the following illustrations.
Installation Model: OVH-10-C 2-06. Final Countertop Installation 1. Confirm that both the Hood and cooking appliance are properly wired and that electrical installation is complete. 2. Ensure that the Hood is positioned in its final location and that it is suitably level and stable.
Overview Model: OVH-10-C 3. Overview The following section provides a brief overview of the components, functions, and accessories of the OVH-10-C Ventless Countertop Hood. Please review this section carefully before attempting to operate the unit. Hood Exhaust Filter Access Door...
Model: OVH-10-C Overview 3-01. Control Panel ILS Only...
Page 27
Overview Model: OVH-10-C 3-01. Control Panel Item Description Function The Power Switch is a two-position Switch. Placing switch in Power Switch the ON position starts the hood fan. After placing Power Switch in the ON position, push and hold PUSH TO START button for approx.
Model: OVH-10-C Overview 3-02. Hood Front & Filter Chamber Not Shown...
Page 29
Overview Model: OVH-10-C 3-02. Hood Front & Filter Chamber Item Description Function Provides access to the Baffle Filter, EAC and Charcoal Filter. Filter Access Door This door must be in place and secure for the unit to oper- ate. First stage of the grease extraction and air-cleaning system.
Model: OVH-10-C Overview 3-03. Accessories (Standard) Part Description/Part Number Function Removes large particle Baffle Filter contaminant from the air 45096 stream. EAC Filter Removes smoke and fine parti- 22360 cle contaminant from the air stream. Charcoal Filter Helps to remove cooking odors 31963 from the discharged air.
Overview Model: OVH-10-C 3-03. Accessories (Standard) Part Description/Part Number Function EAC Soak Tank Use for soaking and cleaning 39327 EAC filter. 3-04. Accessories (Optional) Part Description/Part Number Function...
Model: OVH-10-C Operation & Filter Maintenance 4. Operation & Filter Maintenance This section describes Hood operation, care and cleaning of Filters, and other general maintenance items. 4-01. Hood Operation Confirm that all Filters are in place and properly seated before attempting to operate the hood. The Filter Access Door must be in place and secure.
Model: OVH-10-C Operation & Filter Maintenance 4-02. Hood Filter System The OVH-10-C Hood Filter System consist of three (3) stages. This section describes filter maintenance and cleaning procedures necessary to keep the air cleaning system at peak performance. 4-02.1. Ventless Hood Filter Table...
Operation & Filter Maintenance Model: OVH-10-C 4-02.2. Filter Removal - Baffle, EAC & Charcoal Remove Filter Access Door Place in OFF position To remove, simply slide the desired Filter straight out of its Filter Chamber track.
Model: OVH-10-C Operation & Filter Maintenance 4-02.3. Filter Installation - Baffle, EAC & Charcoal To reinstall Filters, align with the filter channel and slide straight in until filter hits a stop. Note airflow direction arrows on filters when reinstalling. Reinstall Access Door 4-02.4.
Operation & Filter Maintenance Model: OVH-10-C 4-02.6. EAC Filter Status Three L.E.D. indicator lights on the Control Panel display the status of the EAC Filter System. When this is the only L.E.D. ON, the EAC Filter is in place, powered and operating properly.
Model: OVH-10-C Operation & Filter Maintenance 4-03.2. EAC Filter Cleaning The EAC Filter must be cleaned daily for peak performance. Failure to do so will eventually lead to filter system failure and reduce Charcoal Filter life. Follow the procedure below for effective cleaning.
Operation & Filter Maintenance Model: OVH-10-C 4-04. Filter Alarm Chart Filter Alarm Sound What will happen Cause Solution See Section affected Alarm sounds, Charcoal or Baffle Filter Clogged lamp illuminates, Filter dirty and power to the appliance is 4-02.02. &...
Model: OVH-10-C Hood Cleaning & Maintenance This Section describes the steps to generally maintain and clean the OVH-10-C Hood. Attention to these procedures will help ensure the hood remains in good operating condition and continues to run efficiently and safely.
Model: OVH-10-C Hood Cleaning & Maintenance 5-02. Hood Cleaning CAUTION DO NOT wash down hood with water from a spray hose. DO NOT steam clean or use any type pressure washer. DO NOT use products containing chlorine or other caustic chemicals.
Model: OVH-10-C Model: OVH-10-C 6. Trouble Shooting This section describes basic troubleshooting procedures for the OV H - 10 - C H o o d . The wiring diagram attached inside the back cover is provided to assist qualified technicians with more in-depth troubleshooting.
Page 46
Model: OVH-10-C Troubleshooting 6-01. Troubleshooting Procedures (Continued) Problem Probable Cause Corrective Action Appliance will not heat ... a. Baffle Filter missing or not Install Baffle Filter or check • Hood Powered light ON properly installed alignment. • light ON FILTER MISSING b.
Please visit our website at: www.gfse.com or e-mail services@gfse.com. The goal of the Giles team is to provide you with the highest quality service and assistance possible. To help us accomplish this please have the following information readily available when calling, along with the nature of the problem you are encountering.
Page 54
Giles Enterprises, Inc. 2750 Gunter Park Drive West • Montgomery, Al 36109 USA Phone 334.272.1457 • Toll Free 800.554.4537 (USA & Canada Only) • FAX 334.239.4117 • www.gfse.com Form No. 65906 (Release Date 8/27/12: Rev. A)
Need help?
Do you have a question about the OVH-10-C and is the answer not in the manual?
Questions and answers