Summary of Contents for GILES OVH-10

  • Page 1 Operations & Service Manual OVH-10 / PO-VH Model: OVH-10 Model: PO-VH ISO 9001-2015 Registered • Committed to Quality 2750 Gunter Park Drive West • Montgomery, AL 36109 USA Phone: 334.272.1457 • Toll Free: 800.554.4537 (USA & Canada Only) Fax: 334.239.4117 • Website: www.gfse.com...
  • Page 3: Limited Warranty

    • During the Limited Warranty period, Giles will replace or recondition, at its factory, any part or parts of this unit which Giles inspectors judge defective, provided the unit has been properly installed, subjected to nor- mal usage, and operated and maintained in accordance with specified procedures.
  • Page 5: Safety Overview

    The instructions contained in this manual have been prepared to aid in learning the proper procedures for installing, operating and servicing Giles Model OVH-10 & PO-VH Ventless Recirculating Hoods. Throughout the manual, safety precautions are identified by a hazard alert symbol and key words such as DANGER, WARNING or CAUTION.
  • Page 6: Specific Safety Precautions

    Safety Specific Safety Precautions: For your safety, please observe the following precautions when operating or servicing the Model OVH-10 or PO-VH Ventless Recirculating Hoods. Adhering to the following important safety information will help to prevent personal injury and/or damage to the equipment.
  • Page 7 Safety OVH-10 / PO-VH Specific Safety Precautions: • Exercise care when removing wooden crate framework and the unit from shipping pallet. • DO NOT operate the appliance, unless its components and their intended functions are fully understood (see Section 3). Once you have read and fully understand Section 3, closely follow the instructions presented in this Operations Manual in order to prevent equipment damage, or malfunction.
  • Page 8 OVH-10 / PO-VH Safety NOTE: ▪ When received, If damage to the shipping pallet is evident, immediately and thoroughly inspect the equipment and it accessories. Notify the freight company of any damages. Generally, negotiating freight damage claims shall be the responsibility of the Customer.
  • Page 9: Standard Features

    Ansul® Dealer. • Power Plug & Receptacle (OVH-10 ONLY): OVH-10 Hood can be equipped with a power cord and plug, along with an interlocked appliance power receptacle. Makes unit completely “plug & play”.
  • Page 10 OVH-10 / PO-VH Introduction 1.04 Specifications 1.04.1 Overall Dimensions: PO-VH [UCM Model] 42.483 62.324 1079.08 1583.03 41.528 60.410 1054.82 1534.42 29.406 48.330 746.91 1227.57 47.029 23.000 C TO C C TO C 1194.54 584.2 5/16-18 MOUNT NUT (4) PLCS. EQUIPMENT HEIGHT...
  • Page 11 Introduction OVH-10 / PO-VH 1.04.2 Overall Dimensions: OVH-10 [UCM Model] OPTIONAL EXTINGUISHER PIPING AND FUSIBLE LINK SYSTEM FOR HOOD (4) 5/16-18 COUPLING NUTS FOR CEILING MOUNTING 30 3/8 771.09 24 7/16 620.73 28 7/8 17 1/4 C TO C C TO C 733.91...
  • Page 12: Agency Certifications

    1.04.6 Appliance Constraints: OVH-10 Hood Unit Type Max. Total Input, Max. Clearance Electric Oven 11.5 30” [762mm] to cooking surface Electric Rotisserie 6” [153] to door top PO-VH & OVH-10 Recirculating Ventless Hoods CANNOT be used for gas heated appliances.
  • Page 13: Installation

    OVH-10 / PO-VH Installation This section summarizes the procedures necessary to install your new PO-VH or OVH-10. Before installing this equipment, please thoroughly read the contents of this manual and any accompanying installation instructions. Before installing this equipment secure all necessary approvals from appropriate authorities having jurisdiction (electrical/mechanical, fire marshal, health department.
  • Page 14 Model: PO-VH & OVH-10 Installation 2.02 Unpacking Unit is shipped on a wooden pallet, secured by high-tensile plastic strapping and wrapped in machine-applied stretch wrap. In most cases a wooden framework is built around the unit for added protection. Unpack unit as follows: 1.
  • Page 15: Electrical Specification

    PO-VH IMPORTANT! • PO-VH & OVH-10 Hoods are designed to operate with either 208V or 240V supply power; the table above shows different amp draw at each voltage. • Breaker sizes shown apply to Hood power only. Power to the served appliance is typically interlocked through the Hood so that the both are powered through the same breaker.
  • Page 16: Electrical Connections

    Model: PO-VH & OVH-10 Installation 2.04 Electrical Connections Confirm that the appropriate circuit breakers are installed in the main electrical panel supplying power. Refer to table in Section 2.03. Connect appropriately size wire at the main breaker. As applicable, allow enough wire length so the unit may be moved for cleaning and servicing.
  • Page 17: Electrical Connections For Installation Over A 480V Appliance

    • Connect appliance power wires to terminal blocks A1, A2, A3, G (outgoing power). • Should there be any question as to proper connection procedures call Giles Technical Service - 800.554.4537. • If hood is equipped with Fire Suppression System option connect as directed.
  • Page 18 OVH-10 / PO-VH Installation 2.05 Skirt Corner Guards [certain PO-VH Models Only] Some PO-VH Models are supplied with a Skirt Corner Bumper Guard Kit (2 pieces). Use of these can help prevent personal injury to persons who may inadvertently contact with the overhanging front corners of the Hood Skirt.
  • Page 19 Some jurisdictions require that a Fire Suppression System be provided for this type Hood, regardless of the application. Giles PO-VH and OVH-10 model hoods can be ordered with optional factory-installed fire system pre- plumbing which includes piping, discharge nozzles, exhaust fire damper and detector link brackets & conduit.
  • Page 20 OVH-10 / PO-VH Installation 2.06.2 Fire Suppression - Final System Installation An Ansul® Service Agent shall install a regulated extinguisher release mechanism and tank, and tie-in necessary connecting piping, detector link conduit to the Hood connection points. Appropriately rated fuses will be installed in detector brackets and connected with stainless steel wire cabling throughout the fusible link conduit circuit.
  • Page 21 OVH-10 / PO-VH Overview The following section provides a brief overview of the components, functions, and accessories of the PO-VH and the OVH-10 Ventless Hood. It will be very helpful to thoroughly review this section before proceeding. Hood Exhaust w/Diverter Control Panel Figure 3.1...
  • Page 22 OVH-10 / PO-VH Overview 3.01 Control Panel: PO-VH...
  • Page 23 Overview OVH-10 / PO-VH 3.01 Control Panel: PO-VH Item Description Function The Power Switch is a 3-position Switch. Press and momentarily hold the top [START] portion of the switch to start the Hood and Power Switch supply power to the interlocked appliance. When released, switch remains in the [ON] (centered) position.
  • Page 24 OVH-10 / PO-VH Overview 3.01.1 Control Panel: OVH-10...
  • Page 25 Overview OVH-10 / PO-VH 3.01.1 Control Panel: OVH-10 Item Description Function EAC L.E.D. ON to indicate that the Electronic Air Cleaner (EAC) is powered. ON Indicator The EAC is operating normally when this is the only LED indicator illuminated. When these Indicators are ON, the EAC Cell has stopped functioning.
  • Page 26 OVH-10 / PO-VH Overview 3.02 Filter Chamber & Exhaust OVH-10 * Not Shown for POVH...
  • Page 27 Directs exhaust air to the sides and rear, allowing installation of Air Diverter Hood with less ceiling clearance. Zero [0”] clearance is required from top of Diverter to ceiling. IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty. * Not Shown for POVH...
  • Page 28: Accessories Included

    Helps eliminate cooking aromas Charcoal Filter from the exhausted air stream. P/N 30248 [PO-VH] NOT A CLEANABLE FILTER P/N 31963 [OVH-10] NOTE: NO FILTER COMPLETELY REMOVES ODORS IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
  • Page 29 Overview OVH-10 / PO-VH 3.03 Accessories Included Part Description/Part Number Function Holding tank for degreasing solution needed for soaking the EAC Soak Tank EAC Filter Cell during the daily P/N 39327 cleaning process. Provided with drain valve for emptying tank.
  • Page 30 OVH-10 / PO-VH Overview...
  • Page 31: Hood Operation

    Operation & Filter Maintenance OVH-10 / PO-VH Operation & Filter Maintenance This section explains Ventless Hood operation, required filter maintenance and cleaning, and alarm conditions. 4.01 Hood Operation Before attempting to operate the Hood, be certain that all Filters are in place and properly installed.
  • Page 32: Operation & Filter Maintenance

    OVH-10 / PO-VH Operation & Filter Maintenance 4.02.2 Accessing the Filter Chamber ① Although removing Cover/opening Door will cause Hood to shutdown, always place Power Switch in [OFF] position before opening the Filter Chamber. Opening the Filter Chamber POVH ②...
  • Page 33 Operation & Filter Maintenance OVH-10 / PO-VH 4.02.2 Accessing the Filter Chamber - continued Closing the Filter Chamber POVH ② ① ① Grasp Handle, insert upper edge & slide Cover upward; ② Push Cover in at bottom, ③ Pull Cover downward to secure behind flange.
  • Page 34 OVH-10 / PO-VH Operation & Filter Maintenance 4.02.3 Filter Management 4.02.3.1 Baffle Filter Removal/Installation ① Place Power Switch in [OFF] position A. Removing Filter: emove Cover [POVH] or open Access Door ② Grasp Filter & pull straight out ② [OVH-10] of the Filter Chamber.
  • Page 35 [OVH-10] B. Installing E.A.C. Filter Cell Filter Contact emove Cover [POVH] or Plate open Access Door [OVH-10] Hood Contact Plate Align Filter cell in guide channels with Contact Airflow indicator arrow must point left. Plate to the back and slide straight into the Filter Chamber to stop.
  • Page 36: Charcoal Filter Removal/Installation

    4.02.3.3 Charcoal Filter Removal/Installation ① Place Power Switch in [OFF] position A. Removing Filter emove Cover [POVH] or open Access Door [OVH-10] ② ② Grasp Filter & pull straight out of the Filter Chamber. B. Installing Filter Align Filter in guide channels & slide straight into the Filter Chamber to stop.
  • Page 37: Charcoal Or Baffle Filter Clogged

    Operation & Filter Maintenance OVH-10 / PO-VH 4.02.4 Hood Filter Alarms 4.02.4.1 Charcoal or Baffle Filter Missing If the Charcoal Filter or Baffle Filter is not in place, or not positioned correctly, the red [CHARCOAL OR BAFFLE FILTER MISSING] light will turn ON.
  • Page 38 3. Inspect the Filter Cell for broken or missing ionizer wires, bent fins, or other damage. Ionizer wires are replaceable (POVH: P/N 21153 ... OVH-10: P/N 21180); bent fins may be straightened by hand. An excessively damaged Cell (broken, bent frame, etc) will need to be replaced.
  • Page 39: Filter Cell Cleaning

    Baffle Filter Cleaning Generally, the Baffle Filter should be cleaned daily. Wash Filter in sink using a mild, non-caustic, bio-degradable degreasing cleaner (Giles recommends Simple Green®). Rinse and dry thoroughly before reinstalling in Hood. NEVER place a wet filter into Hood.
  • Page 40: Charcoal Filter Maintenance

    Typical replacement cycle is every 30 to 40 days, depending on usage. Use Giles replacement Part No. 30248 (PO-VH) or 31963 (OVH-10). Record replacement date on the new filter. IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
  • Page 41 ▪ Remove the Filter Cover (POVH) or open Filter Door (OVH-10). ▪ Remove all the Filters from Hood. Using a mild, non-caustic, bio-degradable, degreasing cleaner (Giles recommends Simple Green®) and a soft cloth or sponge, clean all surfaces within the Hood Plenum, including the Filter Channels and EAC Contact Pad.
  • Page 42 GIL S or an authorized service provider. NOTE: Anytime the Filter Access Cover (POVH) is removed and replaced, or Door (OVH-10) is opened and reclosed, the Hood must be restarted by pressing and momentarily holding the top [START] portion of the Power Switch.
  • Page 43 OVH-10 / PO-VH Hood Cleaning & Maintenance 5.03 Fire Suppression System Maintenance (Only for Hoods w/Required Fire System) Should the installed Hood be equipped with a required fire extinguishing system, it must be maintained according to the Standard for Wet Chemical Extinguishing Systems, NFPA 17A and in accordance with the instructions of the system provider.
  • Page 44 OVH-10 / PO-VH Hood Cleaning & Maintenance 5.03.3 12-Year Inspection & Maintenance Same as annual inspection and maintenance except: 1. Replace wet-chemical fire suppressant. 2. Hydrostatic test and certify Suppressant Tank and Compressed Gas Charging Cartridge. As alternative components can be replaced with new.
  • Page 45 OVH-10 / PO-VH Hood Cleaning & Maintenance 5.04 Inspection & Maintenance Log Check Initial/Date Check Initial/Date BC 1/31/12 Cover/Door Test Section 5.02 Baffle Filter Missing Test Section 5.02 E.A.C. Filter Cell Missing Test Section 5.02 Charcoal Filter Missing Test Section 5.02 Filter Clogged Test Section 5.02...
  • Page 46: Troubleshooting Procedures

    OVH-10 / PO-VH Troubleshooting Troubleshooting This section describes troubleshooting procedures for PO-VH and OVH-10 Ventless Oven Hoods. These procedures are generally presented as an aid for qualified Technicians and service providers. Users should limit troubleshooting only to matters involving operting procedures.
  • Page 47 Troubleshooting OVH-10 / PO-VH 6.01 Troubleshooting Procedures Problem Probable Cause Repair Procedure Appliance will not operate a. Baffle and/or Charcoal Filter Install Baffle and/or Charcoal Filter. • Hood power is ON missing • [CHARCOAL OR BAFFLE FILTER Reinstall Baffle and/or Charcoal Filter, b.
  • Page 48 OVH-10 / PO-VH Troubleshooting...
  • Page 49: Parts List

    Website: Email: Our goal at Giles is to provide the highest possible quality of service and assistance. To help us accomplish this, please have the following information readily available when calling, along with a brief description of the problem being experienced. Please record the unit information in the table below for quick reference.
  • Page 50 OVH-10 / PO-VH Parts List 7.02 Control Panel: PO-VH * Hidden...
  • Page 51 Parts List OVH-10 / PO-VH 7.02 Parts List, Control Panel: PO-VH ITEM PART NO. DESCRIPTION 21441 SWITCH, ROCKER, (ON)-0N-OFF, 250V, 20A 24209 L.E.D. CLUSTER, AIR FILTER, E.A.C. 30833 BRACKET, E.A.C. LED (behind Panel) 20398 INDICATOR LIGHT, GREEN, 250V, 0.5W 20399 INDICATOR LIGHT, AMBER, 250V, 0.5W...
  • Page 52 OVH-10 / PO-VH Parts List 7.03 Control Panel: OVH-10 * Hidden...
  • Page 53 Parts List OVH-10 / PO-VH 7.03 Parts List, Control Panel: OVH-10 ITEM PART NO. DESCRIPTION 21441 SWITCH, ROCKER, (ON)-0N-OFF, 250V, 20A 24209 L.E.D. CLUSTER, E.A.C. FILTER 93995 L.E.D. MOUNTING BRACKET 20398 INDICATOR LIGHT, GREEN, 250V, 0.5W 20399 INDICATOR LIGHT, AMBER, 250V, 0.5W 20402 INDICATOR LIGHT, RED, 250V, 0.5W...
  • Page 54 OVH-10 / PO-VH Parts List 7.04 Fan Compartment: PO-VH Internal View Side Access View...
  • Page 55 Parts List OVH-10 / PO-VH 7.04 Parts List, Fan Compartment: PO-VH ITEM PART NO. DESCRIPTION 20303 6 or 7 TERMINAL BLOCK, 4-12 GA WIRE 20319 TERMINAL BLOCK, 50 AMP, AWAG 8-24 20304 TERMINAL BLOCK, GROUND, 4-12 GA WIRE 20320 TERMINAL BLOCK, GROUND, AWAG 8-24...
  • Page 56 OVH-10 / PO-VH Parts List 7.05 Fan Compartment: OVH-10 Internal View Side Access View...
  • Page 57 Parts List OVH-10 / PO-VH 7.05 Parts List, Fan Compartment: OVH-10 ITEM PART NO. DESCRIPTION 20303 6 or 7 TERMINAL BLOCK, 4-12 GA WIRE 20319 TERMINAL BLOCK, 50 AMP, AWG 8-24 20304 TERMINAL BLOCK, GROUND, 4-12 GA WIRE 20320 TERMINAL BLOCK, GROUND, AWG 8-24...
  • Page 58 OVH-10 / PO-VH Parts List 7.06 Filter Compartment: PO-VH * Not shown...
  • Page 59 BAFFLE FILTER, 20” X 20” X 2” (NOT SHOWN) 20520 E.A.C. FILTER CELL, 20” (NOT SHOWN) 30248 CHARCOAL FILTER ASSEMBLY, 20” X 12-3/8” (NOT SHOWN) IMPORTANT! Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty. * Not shown...
  • Page 60 OVH-10 / PO-VH Parts List 7.07 Filter Compartment: OVH-10 * Not shown...
  • Page 61 31963 CHARCOAL FILTER, ASSEMBLY, 16” X 12-3/8” (NOT SHOWN) IMPORTANT! Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty. NOTE: Complete Door Assembly includes Door, Latch, Hinges and all Gaskets installed. * Not shown...
  • Page 62 OVH-10 / PO-VH Parts List...
  • Page 64 2750 Gunter Park Drive West • Montgomery, Al 36109 USA Phone: 334.272.1457 • Toll Free: 800.554.4537 (USA & Canada Only) • FAX: 334.239.4117 • www.gfse.com Form No. 60203 (Rel. Date: Feb.2001, Rev. Date: Oct.2018, Rev. H)