Martin RUSH CS Series User Manual page 6

Cs psu power supply unit
Table of Contents

Advertisement

Before using the fixture, check that all power distribution equipment and cables are in
perfect condition and are of suitable type for the location (including water, pollution,
temperature and UV resistance).
Do not immerse the fixture in water or any other fluid, or install it in a location where
flooding may occur.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (Ta) exceeds 45° C (113° F).
The surface of the fixture can reach up to 55° C (131° F) if the fixture is operated at the
maximum permitted ambient temperature. Allow the fixture to cool for at least 5 minutes
before handling.
Install the fixture on a non-combustible surface (brick, concrete, plaster etc.) only.
Do not aim the fixture towards combustible materials (fabric, wood, paper etc.) that are
within 10 cm (4 in.) of the fixture.
Keep the fixture well away from flammable materials (volatile liquids etc.).
Ensure that there is free and unobstructed airflow around the fixture.
Allow at least 0.1 m (4 in.) free space around the fixture.
Do not attempt to bypass thermostatic switches or fuses.
Do not modify the fixture in any way not described in this manual or install other than
genuine Martin® parts. Do not stick filters, masks or other materials onto any lens or other
optical component. Use only accessories approved by Martin® to modify the light beam.
Protection from eye injury
The CS Series fixtures fall into Risk Group 2 according to EN62471. To minimize the risk
of eye irritation or injury, disconnect the fixture from power at all times when the fixture is
not in use, and provide well-lit conditions to reduce the pupil diameter of anyone working
on or near the fixture.
The light from the LED emitters is possibly hazardous and may be harmful to the eyes. Do
not stare directly into the product's light output.
Do not look at the light output with magnifiers, telescopes, binoculars or similar optical
instruments that may concentrate the light output.
Ensure that persons are not looking directly into the fixture when the product lights up
suddenly. This can happen when power is applied, when the product receives a DMX
signal, or when certain control menu items are selected.
WIDE fixtures
The CS Series Wide fixtures fall into the following risk groups according to EN62471 at the
distances indicated below. Position the CS Series Wide fixtures so that prolonged staring
into the light output at less than 336mm (13.3 in.) from the fixture is not expected.
336 mm
3.4 m
(13.3 in.)
(11.2 ft.)
RISK GROUP
RISK GROUP
RISK GROUP
2
1
EXEMPT
6