Figure 99: Ac-Dc Charger Wiring Instructions; Table 18: Specifications For Solar Panels - ABB XSeriesG4 User Manual

Flow computer
Hide thumbs Also See for XSeriesG4:
Table of Contents

Advertisement

Clip the negative lead of the MM to the other side of the test resistor.
Determine if the loaded voltage is greater than or equal to the specification listed in Table 18:.
-
If solar panel is not above the minimum.
-
Replace solar panel.
-
Retest.
Return to the Power Troubleshooting flowchart and continue testing, if the issue still exists.
Panel
10
20
30
7.3.4 AC Charging System Test
If the system setup includes an ac charger connected to the flow computer, and it is not supplying the required voltage to the
unit, it may be necessary to test the ac charger.
7.3.4.1
Step by Step Instructions
To perform a test on the ac charging system:
Verify that all the wiring is correct:
-
Check the dc wiring to the J5 charger input termination block connector (Figure 99:).
Verify the primary ac voltage input level is correct.
-
Check the input ac power supply voltage to the external ac charging unit.
Verify the dc output from the charger.
-
If there is no dc output from the charger, replace charger fuse (Figure 99:).
-
If the fuse is not faulty, or there is no charger dc output voltage after replacing the fuse, replace the ac charging
unit.
If an issue still exists, return to the Power Troubleshooting flowchart and continue testing.
J17 CHARGER
INPUT
CONNECTOR
7.3.5 Auxiliary Equipment Isolation Test
This test will need to be performed if your battery pack output voltage is not remaining consistent and no errors were found
during the previous Power Supply, Solar Panel Charging System or AC Charging Circuit troubleshooting tests.

Table 18: Specifications for Solar panels

Max
Volts @P
Open Circuit
Max
10W
16.8V
21V
20W
16.8V
21V
30W
16.8V
21V
BLK
GROUND TO ENCL.
RED
REPLACEABLE
F2-2AMP FUSE

Figure 99: AC-DC Charger Wiring Instructions

149
Load Resistance
Loaded Voltage
30 Ω 25W
16–18Vdc
15 Ω 25W
16–18Vdc
10 Ω 40W
16–18Vdc
AC - HOT
AC - NEUTRAL
AC - GROUND
XFC G4 2103335 Rev AB
AC IN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents