Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
0B6F
DIMM group with
error is enabled
0B70
The error occurred
during temperature
sensor reading
0B71
System Temperature
out of the range
0B74
The error occurred
during voltage
sensor reading
0B75
System Voltage out
of the range
0B78
The error occurred
during fan sensor
reading
0B7C
The error occurred
during the redundant
power module
confirmation
0B80
BMC Memory Test
Failed.
0B81
BMC Firmware Code
Area CRC check
failed.
0B82
BMC core hardware
failure.
0B90
BMC Platform
Information Area
Corrupted.
0B93
BMC SDR
Repository empty.
0B95
BMC FRU device
failure.
0B96
BMC SDR
Repository failure.
0BA0
Address Array on
CPU Box #1 error
0BA1
Address Array on
CPU Box #2 error
0BA2
Data Array on CPU
Box #1 error
0BA3
Data Array on CPU
Box #2 error
Description
Memory error was detected.
An error was detected in the
middle of detection of abnormal
temperature.
Abnormal temperature was
detected.
An error occurred during detection
of voltage.
Abnormal system voltage was
detected.
An error was detected during read
of FAN sensor.
An error occurred while redundant
power supply was configured.
BMC SRAM test error
CRC error occurred in BMC code
area.
A firmware task cannot be ready
due to BMC hardware error.
The platform information area of
BMC is damaged.
No BMC SDR data exists.
Access to SROM that contains the
chassis information failed.
Access to FMEM sector that
contains SDR information failed.
An error was detected in the
address area of the third cache for
the CPU backboard #1.
An error was detected in the
address area of the third cache for
the CPU backboard #2.
An error was detected in the data
area of the third cache for the
CPU backboard #1.
An error was detected in the data
area of the third cache for the
CPU backboard #2.
Action
The system is forcibly started because
errors are detected in all memory
devices. Contact your service
representative to replace the DIMM
boards.
Contact your service representative to
replace the I/O riser board, or system
I/O board or baseboard.
Contact your service representative to
replace the power unit.
Contact your service representative to
replace the I/O riser board.
Contact your service representative to
replace the baseboard.
Contact your service representative to
replace the riser card.
Contact your service representative to
replace the CPU backboard.
Problem Solving 5-33