NEC EXPRESS5800/180Ra-7 User Manual page 189

Hide thumbs Also See for EXPRESS5800/180Ra-7:
Table of Contents

Advertisement

Table 5-1. Power On LCD Error Messages (continued)
Error Message
Description
SMI timeout
SMI timeout
Slot PWR Fail 11
Power alarm of PCI bus slot #11
Slot PWR Fail 12
Power alarm of PCI bus slot #12
Slot PWR Fail 21
Power alarm of PCI bus slot #21
Slot PWR Fail 22
Power alarm of PCI bus slot #22
Slot PWR Fail 23
Power alarm of PCI bus slot #23
Slot PWR Fail 24
Power alarm of PCI bus slot #24
Slot PWR Fail 31
Power alarm of PCI bus slot #31
Slot PWR Fail 32
Power alarm of PCI bus slot #32
Slot PWR Fail 33
Power alarm of PCI bus slot #33
Slot PWR Fail 34
Power alarm of PCI bus slot #34
SystemBusC-Err 1
Correctable system bus error
SystemBusC-Err 2
Correctable host bus (CPU backboard #1
system bus) error
SystemBusC-Err 3
Correctable host bus (CPU backboard #2
system bus) error
SystemBusU-Err 1
Uncorrectable system bus error
SystemBusU-Err 2
Uncorrectable host bus (CPU backboard
#1 system bus) error
Action
Call your service representative.
Check if the board in the
corresponding PCI bus slot is
mounted correctly and if the slot
tab is locked correctly. If the same
error still occurs when the board is
mounted and locked correctly, call
your service representative.
Check if the CPU and CPU
termination board are mounted
correctly. If the same error still
occurs when they are mounted
correctly, call your service
representative.
Check if the CPU and CPU
backboard #1 are mounted
correctly. If the same error still
occurs when they are mounted
correctly, call your service
representative.
Check if the CPU and CPU
backboard #2 are mounted
correctly. If the same error still
occurs when they are mounted
correctly, call your service
representative.
Check if the CPU and CPU
termination board are mounted
correctly. If the same error still
occurs when they are mounted
correctly, call your service
representative.
Check if the CPU and CPU
backboard #1 are mounted
correctly. If the same error still
occurs when they are mounted
correctly, call your service
representative.
Problem Solving 5-23

Advertisement

Table of Contents
loading