Table 5-1. Power On LCD Error Messages (continued)
Error Message
CPU Missing
CPU T-Trip 01
CPU T-Trip 02
CPU T-Trip 03
CPU T-Trip 04
CPU T-Trip 05
CPU T-Trip 06
CPU T-Trip 07
CPU T-Trip 08
DUMP Request!
Fan Alm 01
Fan Alm 02
Fan Alm 03
Fan Alm 04
L2#1 Volt Alm 00
L2#1 Volt Alm 02
L2#1 Volt Alm 07
L2#1 Volt Alm 09
L2#2 Volt Alm 00
L2#2 Volt Alm 02
L2#2 Volt Alm 07
L2#2 Volt Alm 09
5-18 Problem Solving
Description
CPU slot connection alarm
CPU #1 thermal trip error
CPU #2 thermal trip error
CPU #3 thermal trip error
CPU #4 thermal trip error
CPU #5 thermal trip error
CPU #6 thermal trip error
CPU #7 thermal trip error
CPU #8 thermal trip error
The DUMP switch was pressed.
Fan #1 alarm
Fan #2 alarm
Fan #3 alarm
Fan #4 alarm
Voltage warning:
The CPU #1 L2 cache voltage is too low.
Voltage alarm:
The CPU #1 L2 cache voltage is too low.
Voltage warning:
The CPU #1 L2 cache voltage is too high.
Voltage alarm:
The CPU #1 L2 cache voltage is too high.
Voltage warning:
The CPU #2 L2 cache voltage is too low.
Voltage alarm:
The CPU #2 L2 cache voltage is too low.
Voltage warning:
The CPU #2 L2 cache voltage is too high.
Voltage alarm:
The CPU #2 L2 cache voltage is too high.
Action
Check if the CPU and CPU
termination board are mounted
correctly. If the same error still
occurs when they are mounted
correctly, call your service
representative.
Call your service representative.
Not a failure
Call your service representative.
Check if the VRM for CPU #1 is
mounted correctly. If the same
error still occurs when the VRM is
mounted correctly, call your
service representative.
Check if the VRM for CPU #2 is
mounted correctly. If the same
error still occurs when the VRM is
mounted correctly, call your
service representative.