K-200 series hot water sanitizing single-tank rack conveyor warewashers

Advertisement

K-200, K-200 PW, K-200 LPW, electric heating
Machines without blower dryer, Left-to-Right
Prewash inserted here for
P
K-200 PW and K-200 LPW
table
support
lip
D
3 1/8"
[80mm]
Prewash inserted here for
P
K-200 PW and K-200 LPW
D
9 7/8" [250mm]
K-200: Table-to-table 6'-4 3/4" [1950mm]
K-200 PW: Table-to-table 8' 1/2" [2450mm] ‡
K-200 LPW: Table-to-table 9' 1/4" [2750mm] ‡‡
UTILITY CONNECTIONS
D
Drain
2-15/16" (75mm) OD vertical, gravity-fed
drain outlet (HDPE piping). Optional 3" NPT
male adapter supplied. Recommend
placement directly above 4" floor drain.
Additional piping to drain (if so required) to
be supplied by customer.
Electrical connection
3 (three) individual terminal blocks at locations
shown. Each connection is 4-wire with
ground (no neutral).
Individual disconnect
with lockout/tagout strongly recommended
for each supply (provided by customer).
Incoming leads must be appropriately sized
for electrical supply. Opening(s) in the
machine for the supply lines are NOT
provided and should be executed on-site
using appropriate strain relief device(s).
Refer to Page 10 for supply details.
Vent connection
354 CFM (+120 CFM room air recommended)
K-200 Series • Updated 12-07
control
panel
drain
handle
1 2 3
1'-7 5/8"
3'-11 1/4" [1200mm]
[500mm]
W
Warm water connection (fill)
3/4" NPT female pipe connection
• Temperature 110-140°F (43-60°C)
• Pressure 15-25 PSI
• Initial fill - Refer to Page 10
• Hardness 4-6 grains/U.S. gal.
C
Cold water connection (rinse)
3/4" NPT female pipe connection
• Temperature 50°F (10°C)
• Pressure 15-25 PSI
• Consumption 84.7 U.S. gals./hour
• Hardness 4-6 grains/U.S. gal.
splash guard
[above table]
1 2 3
table
support
lip
C
W
1'-4 1/8" [410mm]
9 5/8" [244mm]
1" [25mm]
W
C
8" [203mm] splash
guard [above table]
K-200 PW: 1'-7 5/8" [500mm] prewash
‡‡
K-200 LPW: 2'-7 1/2" [800mm] prewash
DETAIL VIEW: VENT
The vent shroud MUST NOT be connected directly to the machine, as this
prevents room air from being drawn into the shroud. All dimensions shown
are recommendations only. Actual exhaust connection must be adequate
for the exhaust air and comply with all applicable national and local codes.
The waste air connection must be corrosion-resistant and frost-free. In
particular, provision must be made to prevent air temperatures of 32°F/0°C
or colder from reaching the machine at any time. A provision for draining
moisture from the waste air pipe is STRONGLY RECOMMENDED.
Vent shroud
(supplied
by customer)
Machine
exhaust vent
Horizontal
clearance
1'-8 1/8"
[510mm]
1-3
C
W
D
CSS TOP OPTION
(front view)
9-7/8" [250mm] load
section is replaced with
CSS Top section. Adds
1'-7 5/8" [500mm] to
overall machine length.
D
2'-1 5/8" [650mm]
2'-5 1/2" [750mm]
Ø1'-6" [457mm]
Condensation
channel
Condensation
Ø1'-4"
can be drained
[406mm]
into machine
(drain is
Ø1'-1 3/8"
supplied by
[340mm]
customer)
Gap permits room
air to enter vent shroud
Page 2