Download Print this page

Meiko K-200 Manual page 3

K-200 series hot water sanitizing single-tank rack conveyor warewashers

Advertisement

K-200, K-200 PW, K-200 LPW, electric heating
Machines without blower dryer, Right-to-Left
splash guard
[above table]
1
table
support
lip
C
W
1'-4 1/8" [410mm]
9 5/8" [244mm]
1" [25mm]
W
C
8" [203mm] splash
guard [above table]
DETAIL VIEW: DRAIN
The machine is equipped with a 2-15/16" (75mm) OD vertical, gravity-fed drain. If possible, the
machine drain can simply be positioned directly above a 4" floor drain.
If a floor drain is not in the correct location, or if local codes require a trap, a 3" indirect drain
line may be attached using the supplied boot, clamp, and 3" NPT male adapter.
Choose a piping
material that:
• Complies with
any applicable
local and
national codes
• Is rated for use
with water
temperatures up
to 180°F/82°C
Direct drain
• Is rated for
(recommended
3-12 pH to
if possible)
accommodate
detergents and
rinse aid in the
drain water
K-200 Series • Updated 12-07
control
panel
2
3
drain
handle
Prewash inserted here for
K-200 PW and K-200 LPW
1
2
3
1'-7 5/8"
3'-11 1/4" [1200mm]
[500mm]
K-200: Table-to-table 6'-4 3/4" [1950mm]
K-200 PW: Table-to-table 8' 1/2" [2450mm] ‡
K-200 LPW: Table-to-table 9' 1/4" [2750mm] ‡‡
Machine
drain
Boot
(supplied)
Clamp
(supplied)
3" NPT male
adapter,
HDPE
(supplied)
To 3" indirect
drain line
(supplied by
customer)
Prewash inserted here for
P
K-200 PW and K-200 LPW
table
support
lip
D
3 1/8"
[80mm]
P
D
9 7/8" [250mm]
K-200 PW: 1'-7 5/8" [500mm] prewash
‡‡
K-200 LPW: 2'-7 1/2" [800mm] prewash
DETAIL VIEW: TABLING
Wall clearances shown are for typical 30" D dishtable. Actual clearances will depend
upon table manufacturer and table dimensions.
Feeding and
discharge tables
to be supplied
by others
D
Table lip-in
height
2'-10"
[864mm]
A.F.F.
Horizontal
1-3
D
CSS TOP OPTION
(front view)
9-7/8" [250mm] load
section is replaced with
CSS Top section. Adds
1'-7 5/8" [500mm] to
overall machine length.
1"
[25mm]
max.
22" [559mm]
max.
20-1/2" [521mm]
recommended
clearance
1'-8 1/8"
[510mm]
C
W
D
2'-1 5/8" [650mm]
2'-5 1/2" [750mm]