K-200 Series Technical Specifications
Operating Capacities
Conveyor speed (ft./min.)
Racks per hour
Dishes per hour
Glasses per hour
Consumption:
• U.S. gals./hr
• U.S. gals/rack
Water Specifications
Minimum water temperatures:
Prewash tank (K-200 PW, LPW only) ........... 140°F (60°C)
Wash tank ......................................................160°F (72°C)
Auxiliary rinse ................................................ 165°F (74°C)
Final rinse ......................................................180°F (82°C)
Water requirements:
Incoming water temperature:
• Final rinse connection .................................. 50°F (10°C)
• Fill connection ............................... 110-140°F (43-60°C)
Machine Electrical Specifications
K-200, electric tank heat ............................. 18.3A 66.7A 75.0A
K-200 PW, electric tank heat ...................... 20.9A 66.7A 75.0A
K-200 LPW, electric tank heat .................... 28.1A 66.7A 75.0A
K-200, steam coil tank heat ........................ 18.3A
K-200 PW, steam coil tank heat ................. 20.9A
K-200 LPW, steam coil tank heat ............... 28.1A
CSS Top ...................................................... +3.9A
Blower dryer, electrically-heated machines ...
Blower dryer, steam coil-heated machines ... +16.0A
Component Electrical Specifications
Motors:
Wash pump motor ........................................................... 3.0 hp
Prewash pump motor, K-200 PW .................................. 0.75 hp
Prewash pump motor, K-200 LPW .................................. 3.0 hp
Auxiliary rinse pump motor ............................................ 0.75 hp
Final rinse pump motor .................................................. 0.75 hp
Conveyor motor ........................................................... 0.125 hp
Vent motor ..................................................................... 0.25 hp
CSS Top pump motor ...................................................... 1.0 hp
Blower dryer motor .......................................................... 0.5 hp
Steam Specifications (steam-heated units only)
Steam line connection ................................................ 2" NPT
Condensate return connection ................................... 1" NPT
K-200 Series • Updated 12-07
Low
Medium
High
24.12
5.36
6.57
153
196
240
3,825
4,900
6,000
5,508
7,056
8,640
84.7
84.7
84.7
0.55
0.43
0.35
208 V/60 Hz/3 Ph
TB1
TB2
TB3
--
--
--
--
--
--
--
--
--
--
--
--
--
Conveyor Specifications
Horizontal clearance ................................. 1' 8-1/8" (510mm)
Vertical clearance ............................................ 1' 6" (458mm)
Initial fill:
• K-200 ................................................ 37.0 gallons (140 liters)
• K-200 PW ......................................... 52.8 gallons (200 liters)
• K-200 LPW ....................................... 60.7 gallons (230 liters)
• CSS Top option (all) ................... Add 10.6 gallons (40 liters)
Consumption at 100% capacity ... 84.7 gals. (320.6 liters)/hour
Incoming water line size:
• Final rinse connection ............................................. 3/4" NPT
• Fill connection ......................................................... 3/4" NPT
Flow rate ......................................... 1.4 gpm (5.3 liters/minute)
Recommended max. water hardness ................. 4-6 grains/gal.
230 V/60 Hz/3 Ph
TB4
TB1
TB2
TB3
--
18.3A 58.2A 65.5A
--
20.9A 58.2A 65.5A
--
28.1A 58.2A 65.5A
--
18.3A
--
--
--
20.9A
--
--
--
28.1A
--
--
--
+3.9A
--
--
16.0A
--
--
--
--
+14.0A
--
--
Electric Heating Elements:
Wash tank ........................................................................ 24 kW
Auxiliary rinse tank .......................................................... 12 kW
Booster heater ................................................................. 15 kW
Blower dryer heater ........................................................... 3 kW
Steam pressure ......................................... 10-29 psi (1-2 bars)
Consumption ................................................ 187 lbs./hr. (51 kW)
460 V/60 Hz/3 Ph
TB4
TB1
TB2
TB3
--
8.4A
29.8A 33.7A
--
9.8A
29.8A 33.7A
--
12.3A 29.8A 33.7A
--
8.4A
--
--
--
9.8A
--
--
--
12.3A
--
--
--
+2.3A
--
--
14.0A
--
--
--
--
+9.2A
--
--
TB4
--
--
--
--
--
--
--
9.2A
--