CAUTION:
Do not clean the Nozzle Cover side with a Cleaning Applicator containing the Cleaning
Liquid.
If bubbles and liquid adhere to the side of the Head, it may cause a failure.
CAUTION:
Do not wipe the protrusion of the Nozzle Cover downward as shown below.
The Nozzle Cover may come off causing failure.
Reference: Cleaned the Nozzle Cover
Step 7
Clean the left and right ribs on both ends of the carriage.
Step 8
After cleaning the Nozzle Cover, remove the tray or paper placed under the Head.
Step 9
Close the Front Cover.
Step 10
Press the "END" button.
The carriage moves to the right end, and the Head is capped.