System configuration and wiring

System configuration/ general wiring diagram
Motor extension cable
(option)
Select if needed (up to 10 m).*
GU series
Brushless amplifier
Gear head
GV series
Brushless motor
(option)
AC power supply
Noise
Magnetic
MCCB
filter
contactor
* It is the maximum length in our
evaluation environment,
it does not guarantee the operation
in customer's use environment.
• Wiring work should be performed by qualified electric construction expart.
• Do not turn on power before finishing wiring, to avoid risk of electric shock.
• For details of options (sold separately), see P.74.
16
Digital key pad connecting cable
(option)
Digital key pad
Digital display console.
It enables change of
parameter.
It cannot be used
simultaneously.
POWER
PC connecting cable
(option)
If your PC does not have
RS232 port, use RS232-USB
converter.
Personal computer
(Customer preparation)
Communication software PANATERM for BL
Please download from our web site
Parameter change and control state monitoring
possible.
Wiring equipment
• Recommended noise filter
Voltage
Single phase 100, 200 V
(option)
3-phase
• Selection of Molded Case Circuit Breaker (MCCB), magnetic contactor, and electric wire
(wiring within equipment) (refer to P.64 "Conformance to EC directive and UL standard"
for compatibility with overseas standard.)
Voltage
Single phase
100V
Single phase
200V
3-phase
200V
■ Be sure to ground the grounding terminal.
In wiring to power supply (outside of equipment) from MCCB, use an electric wire of 1.6
mm diameter (2.0 mm
with resistance less than 100 Ω. Do not tighten the ground wires together, please tighten
them individually.
• Selection of relay
As for use for control circuit such as control input terminal, use a relay for small signal
(minimum guarantee current 1 mA or less) for preventing poor contact.
<Example>
Panasonic: DS type, HC type, OMRON: G2A type
• Control Circuit Switch
When using a switch instead of relay, use one for minute current in order to prevent poor
contact.
<Example>
Nihon Kaiheiki Ind.Co.,Ltd: M-2012J-G
Optional part
Manufacturer's
number (option)
part No.
DV0P4170
SUP-EK5-ER-6
DV0PM20042
3SUP-HU10-ER-6
Magnetic
MCCB
Capacity
contactor rated
(
)
rated
current
(W)
current
(contact structure)
50 to 130
5 A
20 A (3P+1a)
50 to 130
5 A
20 A (3P+1a)
50 to 130
5 A
20 A (3P+1a)
) or more both for main circuit and grounding. Must be grounded
2
Manufacturer
OKAYA ELECTRIC
IND. CO., LTD.
Minimum wire size (mm
)
2
(Wiring within equipment)
Main circuit/
Control circuit
Grounding wire
0.5 (AWG20)
0.13 (AWG26)
0.5 (AWG20)
0.13 (AWG26)
0.5 (AWG20)
0.13 (AWG26)
17