Test run (Digital key pad)
Description of
operation
Switch
Press
Press
several times to
[4] Change of
choose parameter 31.
initial setting 2
(Change the
Press
choice of speed
instruction from
Press
to change parameter
analogue speed
value.
instruction input to
" 00 Internal speed
Store by
.
(0-th speed)" to
enable use of
Setting change warning is
Digital key pad.)
issued because setting of
operation instruction has been
changed.
Press
and
at the same
[5] Trip reset
time.
Press
Press
choose several times
to parameter 33.
[6] Choosing
Press
rotation
direction*
Press
to change parameter
(This operation is
value.
not required for
rotation forward
Store by
.
[CCW].)
Setting change warning is
issued because setting of
operation instruction has been
changed.
Press
and
at the same
[7] Trip reset
time.
42
Digital key pad
LED display
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
点滅
点滅
Description of
LED表示
operation
点滅
点滅
Press
点滅
[8] Speed setting
LED表示
点滅
Press
点滅
点滅
点滅
[9] Reset to
Press
点滅
monitor mode.
点滅
点滅
点滅
点滅
[10] Operation
Press
instruction
点滅
点滅
点滅
LED表示
[11] Stop
Press
instruction
[12] Power OFF
点滅
<Checkpoint in Test run>
LED表示
(1) Check whether the motor rotates smoothly. Check for abnormal noise and vibration.
点滅
(2) Check whether the motor is accelerated and decelerated smoothly.
(3) Rotation direction and rotation speed of the motor are matched?
* Rotation direction of gear head output shaft may sometimes be reversed due to
reduction gear ratio when gear head is installed.
点滅
* Rotation direction can also be changed by use of " I 2". See " 33 I 1/ I 2 function
selection" (2) on P.57.
LED表示
点滅
点滅
■ Setting is still stored when power is turned off. When operating the motor with Digital
key pad only in trial run, either reset the setting or initialize parameters after completion
of trial run. (Parameter 54)
Here, note that all parameters return to default when parameters are initialized.
点滅
点滅
Digital key pad
Switch
LED display
Flashing
to set a speed.
Flashing
• Internal speed
(0-th speed) is
displayed (setting
at 0 r/min).
• Set the Internal
speed setting
(0-th speed) at
1800 r/min.
• Data is still stored
if power is cut off
here.
・Display of rotation
speed changes
little by little
toward 1800 r/min
• Display of rotation
direction*
("r" indicates
that the motor is
rotating CW.)
• Display of rotation
speed changes
little by little
toward 0 r/min.
43