Rigging process
Start the standard rigging process by blocking the lower working area, and make sure the work is performed from a stable platform.
1. Check that the clamp is undamaged and can bear at least 10 times the weight of the fixture. Check that the structure can
bear at least 10 times the weight of all installed fixtures, lamps, cables etc.
2. Bolt the clamp securely to the omega bracket with a M12/ ½" bolt (min. grade 8.8) and a lock nut.
3. Align the omega bracket with the two 1/4 turns in the base. Insert the fasteners into the base bracket, and turn both levers
a full1/4-turn clock wise to lock.
4. Working from a stable platform, hang the fixture on a truss or other structure. Tighten the clamp.
5. Install a safety wire that can bear at least 10 times the weight of the fixture. The safety wire attachment point is designed to
fit a carabiner.
6. Verify that there are no combustible materials, cables, or surfaces to be illuminated within 0.3 m (12 in.) of the fixture.
7. Check that there is no risk of colliding between the head / yoke and other fixtures or structures.
WARNING! Always secure an elevated fixture with a safety wire
Fasten a safety wire (not shown) between the load-bearing support structure and the safety wire attachment point on the device.
The safety cable (not included in the package) must:
Bear at least 10 times the weight of the device (SWL)
Have a minimum gauge of 5 mm
Have a maximum length (free fall) = 30 cm (12 in.)
CAUTION!!
Always use a safety wire of a grade AISI 316 steel.
Make sure the slack of the safety wire is at a minimum
Never use the handle for secondary attachment

Tilt Lock

The P-10 can be tilted from 0° - 120.
In standard versions, there is no need for any special tools to adjust the tilt angle.
Take the following steps for adjusting the tilt in standard P-10:
1. Loosen the both tilt screws (one on each side) by turning them counter-clockwise.
2. Adjust the tilt to the angle desired and hold it.
3. Lock the position by re-tightening both tilt lock screws clockwise.
If you feel resistance when tilting the fixture, you might not have loosened the tilt lock screws
wheels enough.
CAUTION!!
If the fixture has been operating, always allow it to cool for 15 minutes before handling.
Exterior surface temperature after 5 min. operation = 45 °C (113 °F). Steady state = 68 °C (154 °F).
Omega bracket
Figure 3: Base with omega bracket
Holes for omega bracket
Figure 4: Safety wire attachment point
Figure 5: Tilt lock
Pitch angle
indicator