Tilt lock

The fixture can be tilted from 0° - 180°.
In Q-2 standard versions, there is no need for any special tools to adjust the tilt angle.
Take the following steps for adjusting the tilt in standard Q-2:
1. Loosen the two tilt screws (one on each side) by turning them counter-clockwise.
2. Tilt the fixture to the angle desired and hold it.
3. Lock the position by re-tightening both tilt lock screws clockwise.
If you feel resistance when tilting the fixture, you might not have loosened the tilt screws enough.
CAUTION!!
If the fixture has been operating, always allow it to cool for 15 minutes before handling.
NOTE: In POI versions, SGM provides a POI Spanner with a pig-nose key for tilt adjustment. Either use the large or the small
pig-nose key, depending on the type of fixture. See page 17 to know more about the tilt lock in Q-2 POI.

Connecting AC power

The Q-2 Series can operate on any 100–277 V, 50/60 Hz AC mains power supply, and it draws approximately 1,2A at full power
(230V).
Connect the fixture to AC power by mounting a power connector to the bare ended mains cable. The fixture must be grounded/
earthed and be able to be isolated from AC power. The AC power supply must incorporate a fuse or circuit breaker for fault protection.
The power cable color coding is given in figure 7:
The fixture must be grounded/
earthed and be able to be isolated
Connect the black wire to live
from AC power. The AC power
Connect the white wire to neutral
supply must incorporate a fuse or
curcuit breaker for fault protection.
Connect the green/yellow wire to ground (earth)
For a temporary outdoor installation the mains cable must be
fitted with a grounded connector intended for exterior use.
For permanent installations, have a qualified electrician to wire the mains cable directly to a suitable branch circuit. The junction's
ingress protection (IP) rating must be suitable for the location. Always use a junction box with a proper IP class suitable for the
environment.
NOTE: In POI versions, the power is wired as the standard versions by mounting a power connector to the bare ended mains
cable. Please refer to pages 17-18 for connecting AC power in POI fixtures.
After connecting a standard Q-2 to power, run the on-board test by selecting the option "TEST→ SELFTEST" in the menu, to ensure
that the fixture and each LED are functioning correctly. POI versions have to be tested through RDM.
CAUTION!!
Do not open the fixture to replace the supplied power cable.
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.
8
Wire
Color
Black
White
green/yellow
Figure 7: Connecting AC Power
Figure 6: Q-2 Standard tilt lock
Symbol
Conductor
L
live
N
neutral
or
ground (earth)