WARNING! Always secure an elevated P-6 with a safety wire
Fasten a safety wire (not shown) between the load-bearing support structure and the safety wire attachment point on the device.
The safety cable (not included in the package) must:
Bear at least 10 times the weight of the device (SWL).
Have a minimum gauge of 4 mm.
Have a maximum length (free fall) = 30 cm (12 in.).
CAUTION!!
Always use a safety wire.
Make sure the slack of the safety wire is at a minimum.
Never use the handle for secondary attachment.

Tilt Lock

The P-6 can be tilted from 0° - 120°. To adjust the tilt angle, loosen both tilt wheels, one on each
side, adjust the tilt to the angle requested, and re-tighten the wheels. There is no need for any
special tools to tighten the wheels. If you cannot feel resistance when tilting the fixture, you might
not have loosened the wheels enough.
Scale function
The P-6 comes with a scale function, which eases the adjustment to the tilt desired.
The pitch indicator in the wheel shows the current angle of inclination.
CAUTION!!
If the fixture has been operating, always allow it to cool for 15 minutes before handling.
Exterior surface temperature after 5 min. operation = 49 °C (120 °F). Steady state = 59 °C (138 °F).

Connecting AC power

The P-6 can operate on any 100–277 V, 50/60 Hz AC mains power supply.
Connect the fixture to AC power using the supplied cable with Neutrik powerCON TRUE1 NAC3FX-W (supplied with the fixture) or
similar with a maximum of 20 A, to ensure the correct ingress protection (IP-rating).
For a temporary outdoor installation, the mains cable must be fitted with a grounded connector intended for exterior use. The fixture
must be grounded/earthed and able to be isolated from AC power. The AC power supply must incorporate a fuse or circuit breaker
for fault protection.
Wire
CAUTION!!
Do not open the fixture to replace the supplied power cable.
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.
After connecting the P-6 to power, run the on-board test by selecting TEST → AUTOMATED TEST in the menu to ensure that the
fixture and each LED are functioning correctly. Please see "Control Menu" on page 13.
PLEASE NOTE:
The protective caps must be securely mounted on any unused DMX connectors in order to maintain the IP66-rating.
Color
Symbol
Black
L
White
N
green/yellow
or
Figure 5: Connecting AC Power
Figure 3: Safety wire attachment point
Conductor
live
neutral
ground (earth)
Pitch angle
indicator
Figure 4: Tilt lock
7