POI Permanent Outdoor Installation

The SGM POI versions are designed for permanent outdoor installation and are IP66-rated or higher. POI versions are designed for
use in maritime and offshore environments, as per the C5-M corrosion-resistance class.
Physical differences
The POI version differs from the standard version by having fixed-chassis power and DMX cables, and heavy-duty cable glands. The
display and control panel have been removed.
Configuration
The P-10 POI does not include a display, therefore it has to be configured through RDM (Remote Device Management).See "RDM"
on page 14 for more information.
In P-10 POI, the DMX address and DMX mode can only be set through RDM. When addressing through USB powered DMX / RDM
devices, ensure DMX link is terminated, and keep a short cable length as far as possible.
Regarding the DMX modes for POI, they are the same as the P-10 standard. Visit www.sgmlight.com to see all DMX charts available
under the respective product, or upon request via support@sgmlight.com.
PLEASE NOTE!!
Remote Device Management (RDM) requires a correct DMX cabled installation and termination.
When setting addresses through RDM and using USB dongles, disable the USB selective suspend to ensure a proper
voltage on the DMX link. If any lag or trouble occurs when addressing, decrease the cable length range to <12 m. and only
address one fixture at a time.
LED Indicator
The LED indicator is located on the fixture's head (same place where the display is located in
standard P-2), and shows the current status of the fixture.
The LED indicator has two different colors and three possible stages: static, flashing, or off.
Static green: fixture is powered on without receiving DMX signal.
Flashing green: fixture is powered on and receiving DMX signal.
Flashing orange (when using the magnet): fixture is connecting to / disconnecting from
an external wireless transmitter.
Static/flashing red: an error message is stored; review via the SGM RDM Addressing
Tool, reboot the fixture, or contact SGM support for diagnostic help.
Off: fixture is off or indicator LED is set to auto dimming (set via RDM).
SGM Addressing Tool
SGM provides a windows software tool designed to allow the user to address and configure the fixtures through RDM. Changing the
settings is done in the exact same way as it is in the display.
This tool is available for download at www.sgmlight.com, and has to be used with the SGM USB 5-Pin-XLR Uploader cable (available
from your SGM dealer).
K
Figure 15: SGM Addressing tool
I
L
Figure 14: P-10 POI LED indicator
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

P-10 poi

Table of Contents