Light Management
Automatic switch 180° 1.10 m
Standard automatic switch 180° 1.10 m
Art.-No.: ..1180..
Universal automatic switch 180° 1.10 m
Art.-No.: ..1180-1..
Operationsmanual

1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Do not press on the sensor window. Device can be damaged.
The device is not suitable for use as a burglar alarm or other alarm.
These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

(1) Flush-mounted insert
(2) Frame
(3) Motion detector cover
(4) Cover plate / slide switch
32540233
J:0082540233
picture 1
1/14
26.07.2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1180 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Jung 1180 Series

  • Page 1: Safety Instructions

    Light Management Automatic switch 180° 1.10 m Standard automatic switch 180° 1.10 m Art.-No.: ..1180.. Universal automatic switch 180° 1.10 m Art.-No.: ..1180-1.. Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the device and result in fire and other hazards.
  • Page 2 Light Management Automatic switch 180° 1.10 m Automatic switch standard picture 2: Automatic switch standard Automatic switch universal picture 3: Automatic switch universal (5) Adjuster, sensitivity (6) Adjuster, brightness (7) Operating mode switch (8) Adjuster, run-on time 3 Function Intended use Automatic switching of lighting depending on the heat motion and ambient brightness.
  • Page 3 Light Management Automatic switch 180° 1.10 m Product characteristics Automatic switch standard Sensitivity and brightness threshold settable Manual switch-on possible via extension insert, 2-wire, or installation button 18 lens segments in 2 recording levels Extension of the detection area in combination with the 3-wire extension insert Detection area can be limited using cover plate i Dimming inserts can only execute switching functions.
  • Page 4 Light Management Automatic switch 180° 1.10 m 4 Automatic switch standard operation Switch on the light via extension A 2-wire extension or an installation button, NO contact is connected. Press extension or installation button. Light is switched on independently of the brightness. Automatic mode is active. i Manual switch-on is not possible.
  • Page 5 Light Management Automatic switch 180° 1.10 m Save switch-on brightness The light is switched to this brightness value on each switch-on. In the as-delivered state, the switch-on brightness is set to the maximum brightness. Motion detector cover is combined with a dimmer insert. A 2-wire extension is connected.
  • Page 6 Light Management Automatic switch 180° 1.10 m Remove slide switch (4). Unscrew locking screw (10) all the way (picture 5) and put it on the back of the slide switch (9) (picture 4). Snap on slide switch and set desired operating mode. i The slide switch can only be locked in automatic mode.
  • Page 7 Light Management Automatic switch 180° 1.10 m Changing the brightness threshold with the Teach function The Teach function can be used to save the current ambient brightness as a brightness threshold. The value set on the Brightness setter (6) is then no longer evaluated. Additional saving operations overwrite the previous value.
  • Page 8 Light Management Automatic switch 180° 1.10 m Presetting the short time operation In conjunction with a switching insert, short-time operation can be set, e.g. to control an acoustic signal encoder. Short-time operation operates independently of the brightness. Remove slide switch (4). Set the run-on time adjuster (8) to the M symbol, short-time operation.
  • Page 9 Light Management Automatic switch 180° 1.10 m picture 9: Detection planes Select a vibration-free installation location. Vibrations can lead to unwanted switching. Avoid interference sources in the detection area. Interference sources, e.g. heaters, ventilation, air conditioners, and cooling light bulbs can lead to unwanted switching. i If necessary, the detection area can be limited using the push-on top (see Limiting the detection area).
  • Page 10 Light Management Automatic switch 180° 1.10 m (15) Sealing flange for IP44 installation (accessories) i IP44 installation is only possible with IP44 automatic switches. Insert the supplied red setscrews (14) for the anti-theft protection into the boreholes of the insert (1) provided for that purpose (picture 10). In the case of IP44 installation insert the sealing flange (15) into an appliance box according to DIN 49073 and install the flush-mounted insert.
  • Page 11 Light Management Automatic switch 180° 1.10 m picture 12: Removing the slide switch Remove slide switch (4) Do this by reaching with a screwdriver into the recesses provided in the cover (picture 12). picture 13: Removing the design cover Remove design cover (11). Do this by reaching with a screwdriver into the point behind the design cover marked with a screwdriver symbol (picture 13) and lift out.
  • Page 12 Light Management Automatic switch 180° 1.10 m i When operating an extension with motion detector covers, it should be noted that the lighting can only be switched on after a lockout time of approx. 3 seconds. 6.2 Commissioning Testing the detection area with automatic switch standard The insert is installed and the cover is attached.
  • Page 13: Troubleshooting

    Light Management Automatic switch 180° 1.10 m Limiting the detection area picture 14: Using cover plate element The supplied cover plate element (12) (picture 14) can be used to cover up the left (17) or right half (18) of the detection field, 90° in each case. Install cover plate element (depending on switch range) (see Installing the motion detector cover).
  • Page 14: Warranty

    We provide a warranty as provided for by law. Please send the unit postage-free with a description of the defect to our central customer service office: ALBRECHT JUNG GMBH & CO. KG Service Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +49 (0) 23 55 .