Drive technology replacing an encoder, encoder replacement
Table of Contents

Advertisement

2.8.2

For SINUMERIK, this is how you backup the electronic type plate data

Preconditions
● You are familiar with SINUMERIK control systems
● SINUMERIK V4.8 or higher
● Access level: "Service" or higher
Procedure
1. Change to operating area: Commissioning > Drive system > Hardware replacement.
2. In the the topology screen, identify the axis with the defective encoder.
3. Press the "Hardwarereplacement" softkey.
4. Select the axis with the defective encoder.
5. Press the "Save SMI/DQI data".
→ after having successfully backed up the data, the following message is displayed.
You have saved the motor and encoder data (the electronic type plate) in the non-volatile
memory of the drive device.
Alternatives
If it is not possible to manually back up the data as a result of the defective encoder, and no
encoder data is saved in the drive system, download the encoder data (the electronic type
plate) from the Internet.
You can find information about this in Chapter "Where can you find the electronic type plate
in the Internet? (Page 48)".
Replacing an encoder for SIMOTICS S-1FK7 G2, S-1FG1 and S-1FT7
Service Manual, 01/2018, A5E34676237B AC
2.8 How do you backup the data of the electronic type plate?
Description