How Do You Order A Replacement Encoder - Siemens SIMOTICS S-1FK7 G2 Service Instructions Manual

Drive technology replacing an encoder, encoder replacement
Table of Contents

Advertisement

2.5

How do you order a replacement encoder?

Note
When ordering, please observe the following:
Encoders with a DRIVE-CLiQ interface have an electronic type plate, which contains the
specific motor and encoder data.
Do you wish to order a DRIVE-CLiQ encoder with loaded data or without data?
Encoder loaded with data
Select "1" as the last digit of the Article number
for the encoder.
Encoder is only designed for one motor (deter-
mined by the article number and the serial num-
ber). The encoder only functions together with
this specific motor.
After the encoder has been mounted, the motor
can completely function.*
Encoders are painted "pearl dark gray" as standard. Replacement encoders for motors with option
N16 or N40 differ from the rest of the motor regarding the paint structure and color.
NOTICE
Motor fault as a result of an excessively high temperature data
If you mount an encoder without data having been loaded to a motor with a Pt1000
temperature sensor – and use a software version SINAMICS < 4.8 or SINUMERIK < V4.8,
then the encoder outputs excessively high temperature values. The temperature monitoring
responds too early.
• In this case, use an encoder with data for your motor loaded in the factory – or program
Data for the temperature sensor installed is stamped on the motor rating plate.
You can find additional information at Identifying the Pt1000 temperature sensor
(https://support.industry.siemens.com/cs/document/109749807/simotics%3Aumstellung-)
We recommend that you order the encoder with the appropriate loaded data as the encoder
can then be quickly and simply replaced.
You can order the encoder in 2 ways.
● You order the encoder from your local Siemens sales person.
● You order the encoder through the online spare parts service of Siemens Industry Mall
You can find details in the following sections.
Replacing an encoder for SIMOTICS S-1FK7 G2, S-1FG1 and S-1FT7
Service Manual, 01/2018, A5E34676237B AC
an encoder without any loaded data as described in Chapter "How do you program an
encoder that has not been loaded with data? (Page 38)".
2.5 How do you order a replacement encoder?
Encoder not loaded with data
Select "0" as the last digit of the Article number
for the encoder.
The encoder can be used with various motors.
You must write the specific motor and encoder
data to the encoder with DRIVE-CLiQ interface.
Description
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1ft7 g2Simotics s-1fg1

Table of Contents