Table 2 : Mantel Shelf Clearances
MAXIMUM MANTEL
SHELF DIMENSION (X)
12" (305mm) max.
9.2

Floor Protection

It is necessary to have a floor protection made of non-combustible materials that meets the
measurements specified in the
Table 3 : Floor Protection
FLOOR PROTECTION
Canada
B
18" (457 mm)
M
8" (203 mm)
N
N/A
From door opening. The depth of the hearth extension in front of the insert is included in the calculation of the floor protector's dimensions. The
1
masonry hearth should be at least 5" (127 mm) higher than the combustible floor in front of it and a floor protection must extend at least 16" (406
mm USA) and at least 18" (457 mm Canada) without an R value. If the hearth elevation is lower than 5" (127 mm), the non-combustible (B) floor
protector in front of the insert should have an R value equal or greater than 1.00 and shall extend 23" (584 mm) in front of the unit.
Page 32
MANTEL SHELF
CLEARANCES (I)
27" (686 mm) min.
«Table 3 : Floor Protection»
USA
16" (406 mm)
1
1
N/A
8" (203 mm)
X
I
Figure 22: Shelf Clearances
below.
B
N
Figure 23: Floor Protection