Controller

6.6 Connecting terminals and interfaces

Installation
Proceed as follows to install the controller:
1. Drill the holes for the screws as shown in the dimension drawing.
2. Secure the controller with 4 (M6 x 10) screws.
6.6
Connecting terminals and interfaces
6.6.1

Wiring instructions

NOTICE
Material damage
Only use cables with a temperature range ≥ 85 °C
Table 6- 5
Slot
X3
X4
X6
X8
60
Properties of slots and interfaces
Name
Maxi-
mum
cable
length
Power supply
< 30 m
24 V voltage output
< 30 m
Digital inputs
> 30 m
Service interface
< 2 m
Type
Not shielded, supply
Not shielded, supply see section Voltage output
(Page 65)
Not shielded, asymmetric data cable
Shielded, symmetric and asymmetric data cable
System Manual, 09/2017, A5E33917696-AD