6.5
Installation
Requirements
The installation site must fulfill the following requirements:
● Minimum clearance to surrounding parts 1 cm
● Even mounting surface
● Maximum distance from the power supply on account of the cable length:
– SIDOOR NT40 / SIDOOR TRANSFORMER / SIDOOR TRANSFORMER UL: 1.5 m
● Maximum distance from the motor on account of the cable length:
– SIDOOR MED280: 1.5 m
Risk of injury as a result of incorrect installation
The controller must only be used indoors.
Final application-specific requirements must be observed.
In an NFPA industrial environment: The controller fulfills the requirements for insulation
against fire only when the cover is closed and, if it is installed outside of a control cabinet,
only when installed horizontally.
In an NFPA elevator environment: Installation must be in an enclosure with insulation
against fire
ATE500E
System Manual, 09/2017, A5E33917696-AD
WARNING
Controller
6.5 Installation
59