Daikin EBLQ011CA3V3 Installer's Reference Manual page 92

Hide thumbs Also See for EBLQ011CA3V3:
Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
A.8
[8-06]
Leaving water temperature maximum modulation.
A.8
[8-07]
What is the desired comfort main LWT in cooling?
A.8
[8-08]
What is the desired eco main LWT in cooling?
A.8
[8-09]
What is the desired comfort main LWT in heating?
A.8
[8-0A]
What is the desired eco main LWT in heating?
A.8
[8-0B]
--
A.8
[8-0C]
--
A.8
[8-0D]
--
A.8
[9-00]
What is the maximum desired LWT for main zone in heating?
A.8
[9-01]
What is the mimimum desired LWT for main zone in heating?
A.8
[9-02]
What is the maximum desired LWT for main zone in cooling?
A.8
[9-03]
What is the mimimum desired LWT for main zone in cooling?
A.8
[9-04]
Leaving water temperature overshoot temperature.
A.8
[9-05]
What is the minimum desired LWT for add. zone in heating?
A.8
[9-06]
What is the maximum desired LWT for add. zone in heating?
A.8
[9-07]
What is the minimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
A.8
[9-08]
A.8
[9-09]
What is the desired delta T in heating?
A.8
[9-0A]
What is the desired delta T in cooling?
A.8
[9-0B]
What emitter type is connected to the main LWT zone?
A.8
[9-0C]
Room temperature hysteresis.
A.8
[9-0D]
Pump speed limitation
A.8
[9-0E]
--
A.8
[A-00]
--
A.8
[A-01]
--
A.8
[A-02]
--
A.8
[A-03]
--
A.8
[A-04]
--
A.8
[B-00]
--
A.8
[B-01]
--
A.8
[B-02]
--
A.8
[B-03]
--
A.8
[B-04]
--
A.8
[C-00]
--
A.8
[C-01]
--
A.8
[C-02]
--
A.8
[C-03]
Bivalent activation temperature.
A.8
[C-04]
Bivalent hysteresis temperature.
A.8
[C-05]
What is the thermo request contact type for the main zone?
A.8
[C-06]
What is the thermo request contact type for the add. zone?
A.8
[C-07]
What is the unit control method in space operation?
A.8
[C-08]
Which type of external sensor is installed?
A.8
[C-09]
What is the required alarm output contact type?
A.8
[C-0A]
--
A.8
[C-0C]
High electricity price decimal (Do not use)
A.8
[C-0D]
Medium electricity price decimal (Do not use)
A.8
[C-0E]
Low electricity price decimal (Do not use)
A.8
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
A.8
[D-01]
Forced off contact type
A.8
[D-02]
What type of DHW pump is installed?
A.8
[D-03]
Leaving water temperature compensation around 0°C.
(*1) *B*CAV3/CAW1_
(*2) *D*CAV3/CAW1_
(*3) *B*CA3*_(*4) *D*CA3*
Range, step
Default value
R/W
0~10°C, step: 1°C
3°C
R/W
[9-03]~[9-02], step: 1°C
18°C
R/W
[9-03]~[9-02], step: 1°C
20°C
R/W
[9-01]~[9-00], step: 1°C
45°C
R/W
[9-01]~[9-00], step: 1°C
40°C
13
10
16
R/W
37~55°C, step: 1°C
55°C
R/W
15~37°C, step: 1°C
25°C
R/W
18~22°C, step: 1°C
22°C
R/W
5~18°C, step: 1°C
5°C
R/W
1~4°C, step: 1°C
1°C
R/W
15~37°C, step: 1°C
25°C
R/W
37~55°C, step: 1°C
55°C
R/W
5~18°C, step: 1°C
5°C
R/W
18~22°C, step: 1°C
22°C
R/W
3~10°C, step: 1°C
5°C
R/W
3~10°C, step: 1°C
5°C
R/W
0: Quick
1: Slow
R/W
1~6°C, step: 0,5°C
1 °C
R/W
0~8, step:1
0 : 100%
1~4 : 80~50%
5~8 : 80~50%
6
6
1
3
0
1
0
0
2
0
0
0
0
0
0
R/W
-25~25°C, step: 1°C
0°C
R/W
2~10°C, step: 1°C
3°C
R/W
1: Thermo ON/OFF
2: C/H request
0~2
1: Thermo ON/OFF
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: Normally open
1: Normally closed
0
R/W
0~7
0
R/W
0~7
0
R/W
0~7
0
R/W
0~3
0: None
1: BSH only
2: BUH only
3: All heaters
R/W
0~3
0: No
1: Open tariff
2: Closed tariff
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
7/8
Installer setting at variance with
default value
Date
Value
4P522033-1A - 2018.06