Daikin EBLQ011CA3V3 Installer's Reference Manual page 59

Hide thumbs Also See for EBLQ011CA3V3:
Table of Contents

Advertisement

#
Code
N/A
[4-03]
<< continuation
The booster heater will be allowed to
operate when T
status of [5-02].
▪ 3 (default): The booster heater is
allowed when the heat pump is NOT
active in domestic hot water operation.
Same as setting  1, but simultaneous
heat  pump
operation
operation is not allowed.
▪ 4: Booster heater operation is NOT
allowed
function".
Only use this in case the capacity of
the heat  pump can cover the heating
requirements
domestic hot water over the complete
heating season.
If the outdoor temperature is below
setting
domestic hot water will not be heated.
The domestic hot water temperature
can be maximum the heat pump OFF
temperature.
When setting [4-03]=1/2/3/4, the booster
heater operation can still be restricted by
the booster heater allowance schedule.
N/A
[7-00]
Overshoot temperature. Temperature
difference above the domestic hot water
set point temperature before the booster
heater is turned OFF. The domestic hot
water tank temperature will increase with
[7-00] above selected temperature
set point.
Range: 0°C~4°C (default: 0°C)
N/A
[7-01]
Hysteresis. Temperature difference
between booster heater ON and booster
heater OFF temperature. The minimum
hysteresis temperature is 2°C.
Range: 2°C~40°C (default: 2°C)
N/A
[6-00]
The temperature difference determining
the heat pump ON temperature.
Range: 2°C~20°C (default: 2°C)
N/A
[6-01]
The temperature difference determining
the heat pump OFF temperature.
Range: 0°C~10°C (default: 2°C)
Example: setpoint (T
)>maximum heat pump temperature–[6‑01]
U
(T
–[6‑01])
HP MAX
EBLQ+EDLQ011~016CA3V3+W1 + EK(2)CB07CAV3
Daikin Altherma low temperature monobloc
4P538847-1 – 2018.05
Description
<[5-03] depends of the
a
domestic
hot
water
and
booster
heater
except
for
"Disinfection
of
the
house
and
[5-03]
and
[5-02]=1,
the
T
DHW
[7-00]
T
73
BH OFF
T
71
BH ON
T
70
U
60
T
50
HP MAX
[6-01]
T
48
HP OFF
[6-00]
T
41
HP ON
40
30
20
HP
10
5
BH
Booster heater
HP
Heat pump. If heating up time by the heat pump takes too
long, auxiliary heating by the booster heater can take place
T
Booster heater OFF temperature (T
BH OFF
T
Booster heater ON temperature (T
BH ON
T
Maximum heat pump temperature at sensor in domestic
HP MAX
hot water tank
T
Heat pump OFF temperature (T
HP OFF
T
Heat pump ON temperature (T
HP ON
T
Domestic hot water temperature
DHW
T
User set point temperature (as set on the user interface)
U
t
Time
Example: setpoint (T
)≤maximum heat pump temperature–[6‑01]
U
(T
–[6‑01])
HP MAX
T
DHW
T
50
HP MAX
T
=T
45
U
HP OFF
[6-00]
T
43
HP ON
40
30
20
HP
10
5
HP
Heat pump. If heating up time by the heat pump takes too
long, auxiliary heating by the booster heater can take place
T
Maximum heat pump temperature at sensor in domestic
HP MAX
hot water tank
T
Heat pump OFF temperature (T
HP OFF
T
Heat pump ON temperature (T
HP ON
T
Domestic hot water temperature
DHW
T
User set point temperature (as set on the user interface)
U
t
Time
INFORMATION
The maximum heat pump temperature depends on the
ambient temperature. For more information, see the
operation range.
Timers for simultaneous request space and domestic hot water
operation
#
Code
N/A
[8-00]
Do not change. (default: 1)
8 Configuration
[7-01]
T
= 70°C
U
[7-00] =
3°C
HP
BH
[6-01] =
2°C
[6-00] =
7°C
+[7-00])
U
−[7-01])
BH OFF
−[6-01])
HP MAX
−[6-00])
HP OFF
t
−[6-01])
HP MAX
−[6-00])
HP OFF
Description
Installer reference guide
59
t