14 Technical data
Electrical connection diagram
Notes:
- In case of signal cable: keep minimum distance
to power cables > 5 cm
- Available heaters: see combination table
Power supply
Only for normal power supply installation
1
3 or 5 core
unit power supply: 400 V or 230 V + earth
1
Only for preferential kWh rate power supply installation
unit preferential kWh rate power supply:
3 or 5 core
400 V or 230 V + earth
2 core
normal kWh rate power supply for unit: 230 V
2 core
2x0.75
Preferential kWh rate power supply contact
Field supply
2 core
Shut-off valve
230V
DHW pump
2 core 230V
Optional part
3 core
Booster heater power supply
(3 kW): 230 V + earth
230 V
Domestic hot
water tank
3
Only for *KHWS*V3
3 core 3Gx2.5
X6M
Booster heater
230 V
3
Only for *KHWP*/*HYC*
3 core 3Gx2.5
K1
Booster heater
230 V
R5T - thermistor
water temperature
signal
3 way valve
M3S (when *KHW is installed)
230 V
selection domestic hot water-floor heating
3 core
Control box power supply: 230 V + earth
Power supply
14.4

ESP curve: Outdoor unit

Note: A flow error will occur when the minimum water flow rate is not
reached.
A (kPa)
100
90
80
70
60
50
40
30
20
10
D
E
0
0
5
10
15
20
Installer reference guide
84
Standard part
Monobloc unit
X1M: L1-L2-L3 or L-N-earth
X4M: L-N + earth
X3M: 5-6
X5M: 5-6
Control box
Optional part
Not for E(B/D)LQ*3V3/3W1
2
Main: X2M: 1-2
X2M: 9-10
Add: X2M: 1a-2
2
X2M: 1-2-1a
2
X2M: 1-2-1a
X8M: 4-5
F2B: 2+4 + earth
2
X2M: 1-2
X8M: 6-7
X4M: 1-2-earth
X4M/X7M: 1-2-earth
X2M: 3-4
X8M: 5-4-3
A4P: X5A: 1-2-3
X1M: L-N-PE
C
25
30
35
40
45
50
B (l/min)
4D117234
Typical configuration
Control
Box
3 core
Backup heater power supply (3 kW): 230 V + earth (F1B)
signal
Optional part
2 core
Only for EKRSCA1
External outdoor thermistor
signal
2 core
2x0.75
communication
External room thermostat / Heat pump convector
(main and/or additional zone)
Dual setpoint application
3 core
(refer to installation manual)
signal
3 core for C/H operation
Only for *KRTW
2 core for H only operation
(wired room thermostat)
A3P: X1M: C-com-H
signal
5 core for C/H operation
Only for *KRTR
(wireless room thermostat)
4 core for H only operation
A7P: X1M: H-C-com
X2M: L-N
230 V
Only for
(heat pump convector)
4 core
X11M: 3-4-5-6
230 V
Optional part
Option box
3 core
A4P: X5A: 1-2-3
communication
3 core
X1M: L-N-PE
230 V
A
External static pressure
B
Water/glycol flow rate
C
Operation range
D
Minimum water flow during normal operation.
E
Minimum water flow during defrost operation.
Notes:
▪ About the dashed lines: The operation area is extended to lower
flow rates only in case the unit operates with heat pump only, and
the temperature of the flow medium is sufficiently high. (This does
not apply to start-up operation, defrost operation, and backup
heater operation in case a backup heater is installed.)
▪ The upper operation range is only valid if the flow medium is
water. If glycol is added to the system, the operation range limit is
lower.
▪ Selecting a flow outside the operating area can damage the unit or
cause the unit to malfunction.
EBLQ+EDLQ011~016CA3V3+W1 + EK(2)CB07CAV3
2 low voltage wires
Standard: 4 low voltage wires
Optional: 4 high voltage wires
Standard part
A5P: P1-P2 user interface
Only for *KRUCB*
2 core
2x0.75
communication
A5P: P1-P2 user interface
Optional part
Optional part
2 core
Only for *KRTETS
(3m included)
R2T
A3P: X1M: 1-3
External sensor
signal
(floor or ambient)
Field supply
2 core
Alarm Output
X2M: 13-15
signal
2 core
X8M: 3-4
Ext. heat source (eg boiler)
230 V
2 core
Space cooling/heating
X8M: 1-2
On/OFF output
230 V
2 core
Electricity pulse
X2M: 7-8
meter input 1
signal
2 core
Electricity pulse
X2M: 9-10
meter input 2
signal
2 core
External indoor thermistor
X2M: 1a-2a
signal
Only for KRCS01-1
4D116771-1
Daikin Altherma low temperature monobloc
4P538847-1 – 2018.05