To Copy The System Settings From The First To The Second User Interface - Daikin EBLQ011CA3V3 Installer's Reference Manual

Hide thumbs Also See for EBLQ011CA3V3:
Table of Contents

Advertisement

Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu title.
The user permission level will stay in Adv. end user until set
otherwise.
To set the user permission level to End user
1 Press
for more than 4 seconds.
Result: The user permission level switches to End user. The user
interface will return to the default home screen.
To modify an overview setting
Example: Modify [1‑01] from 15 to 20.
1 Go to [A.8]:
> Installer settings > Overview settings.
2 Go to the corresponding screen of the first part of the setting by
using the
and
button.
INFORMATION
An additional 0-digit is added to the first part of the setting
when you access the codes in the overview settings.
Example: [1‑01]: "1" will result in "01".
Overview settings
01
00
00
01
15
02
00
04
05
06
08
09
0a
0c
0d
0e
Confirm
Adjust
Scroll
3 Go to the corresponding second part of the setting by using the
and
button.
Overview settings
01
00
00
01
15
02
00
04
05
06
08
09
0a
0c
0d
0e
Confirm
Adjust
Scroll
Result: The value to be modified is now highlighted.
4 Modify the value by using the
Overview settings
01
00
00
01
20
02
00
04
05
06
08
09
0a
0c
0d
0e
Confirm
Adjust
Scroll
5 Repeat previous steps if you have to modify other settings.
6 Push
to confirm the modification of the parameter.
7 At installer settings menu, press
Installer settings
The system will restart.
OK
Cancel
Confirm
Adjust
Result: The system will restart.
8.1.3
To copy the system settings from the first
to the second user interface
If a second user interface is connected, the installer must first
proceed below instructions for the proper configuration of the 2 user
interfaces.
EBLQ+EDLQ011~016CA3V3+W1 + EK(2)CB07CAV3
Daikin Altherma low temperature monobloc
4P538847-1 – 2018.05
03
00
07
0b
0f
03
00
07
0b
0f
and
button.
03
00
07
0b
0f
to confirm the settings.
This procedure offers you also the possibility to copy the language
set from one user interface to the other one: e.g. from EKRUCBL2 to
EKRUCBL1.
1 When power is turned on for the first time, both user interfaces
display:
Tue
U5:Auto address
Push 4 sec. to continue
2 Push
for 4 seconds on the user interface on which you want
to proceed to the quick wizard. This user interface is now the
main user interface.
INFORMATION
During the quick wizard, the second user interface displays
Busy and will NOT be possible to operate.
3 The quick wizard will guide you.
4 For proper operation of the system, the local data on the two
user interfaces must be the same. If this is NOT the case, both
user interfaces will display:
Synchronization
Data difference detected.
Please select action:
Send data
Adjust
Confirm
5 Select the required action:
▪ Send data: the user interface you are operating contains the
correct data and the data on the other user interface will be
overwritten.
▪ Receive data: the user interface you are operating does
NOT contain the correct data and the data on the other user
interface will be used to overwrite.
6 The user interface requests confirmation if you are sure to
proceed.
Start copy
Are you sure you want to
start the copy operation?
OK
Cancel
Confirm
Adjust
7 Confirm the selection on the screen by pushing
(languages, schedules etc.) will be synchronised from the
selected source user interface to the other one.
INFORMATION
▪ During the copying, both controllers will NOT allow
operation.
▪ The copy operation can take up until 90 minutes.
▪ It is recommended to change installer settings, or the
configuration of the unit, on the main user interface. If
not, it can take up to 5 minutes before these changes
are visible in the menu structure.
8 Your system is now set to be operated by the 2 user interfaces.
8 Configuration
15:10
and all data
Installer reference guide
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents