Application Information
Step 7
Use the stylus and the arrow keys on the Meter Test screen to enter/select the number of repeats to
perform.
Step 8
Use the stylus and navigate to the Run Tab. Select the appropriate DUT(s) by checking the
associated box at the bottom of the screen.
Step 9
Tap the RUN Button to initiate the test. Once complete, the Percent Registration, Percent Error,
Test Status, Metric Value, Function Tested, Minimum Percent Registration, Minimum Percent
Error, Minimum Percent Pulses, Minimum Percent Metric, Standard Deviation of Percent
Registration, Standard Deviation of Percent Error, Standard Deviation of Number Pulses and
Standard Deviation of the Metrics being tested are reported.
Step 10
Using the stylus, select the Save Button and navigate to the View Results Tab. Select the View
Results Button and enter the date of the test. Select the View Button to view the results.
11.2 Standards Testing
The RD-30 can be used in the field or in the laboratory to test one (1), two (2) or three (3) single
phase standards or one (1) three phase standards where a high degree of accuracy is required. The
standards test may be achieved by counting a designated number of pulses from the input port(s) or
by counting the number of pulses on from the input port(s) over a designated amount of time. The
input ports can be configured to accept either Radian Research or non-Radian Research standards.
Step 1
Make all appropriate connections (see Figure 10.5) so the Device(s) Under Test (DUT) and RD-30
are powered by the same source.
Step 2
Initiate power on the potential and current sources. Apply power to the RD-30. Upon successful
power up, the RD-30's LED will be green and RR-MobileSuite will have launched (see Section
8.1).
Step 3
Using the stylus, single tap on the Run Standards Test icon. The standards test screen will now
appear (see Section 8.9).