Normal Operating Conditions - Radian RD-30 Operation Manual

Portable three-phase electricity standard
Table of Contents

Advertisement

Specifications
Pickup
Sensor Input Terminal:
Clamp-On CT Input
Transformer Input
3.3 Normal Operating Conditions
Input Potential:
Input Current Options:
Auxiliary Power:
Power Factor 1.0 to 0.5 (0° to -60°)
Power Factor < 0.5 (-60° to -90°)
Operating Temperature:
Storage Temperature:
Humidity:
Frequency:
Orientation:
Recalibration Interval:
Warm-up:
RD-30 Operations Manual
4 Pin Lemo
7 Pin Input for Radian Clamp-On Current
30 - 525 V
at 50Hz (Autoranging)
AC
30 - 630 V
at 60Hz (Autoranging)
AC
V
Not to Exceed (10.5*Frequency)
AC
0.02 - 120 Amperes (Autoranging)
0.02 - 200 Amperes (Autoranging)
Clamp-On Current Transformer
60 - 525 V
at 50Hz (Autoranging)
AC
60 - 630 V
at 60Hz (Autoranging)
AC
V
Not to Exceed (10.5*Frequency)
AC
± 0.01% typical, ± 0.04% maximum
±(0.1%/ PF) maximum
-20°C to 70°C (-4°F to 158°F)
-25°C to 80°C (-13°F to 176°F)
0% to 95% non-condensing
45 to 65 Hertz Fundamental
Any
365 Days
15 seconds
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents