But number
Bit name
04
Blank initial state
05–31
Reserved for future use

6.3 Parameter List

Table 14: Safety Option Parameters
Group
Group
Parameter
name
42-1*
Speed
42-10
Moni-
Measure
toring
Speed
Source
42-11 En-
coder Res-
olution
42-12 En-
coder Di-
rection
42-13 Gear
Ratio
42-14
Feedback
Type
42-15
Feedback
Filter
42-18 Zero
Speed Tim-
er
42-19 Zero
Speed Lim-
it
Danfoss A/S © 2018.09
Value
0
1
Value range/
Default
available op-
tions
[0] None
[1] Safe Op-
tion
[1] Safe Option
1–4096 PPR (for
1024 PPR
option with
HTL encoder)
1–10000 PPR
(for option with
TTL encoder)
[0] Clockwise
[0] Clock-
wise
[1] Counter
clockwise
0.0001–32.0000
1
[0] With direc-
[0] With di-
tion info
rection info
[1] Without di-
rection info
0.01–200.00 Hz
200 Hz
0–10000 h
8760 h
Fixed
120 RPM
Function
Safety option is configured
Safety option is in blank initial state
Description
The source of the speed feedback.
Encoder or proximity switch resolution
of the encoder connected to the MCB
150 TTL and MCB 151 HTL.
Allows for changing the detected en-
coder rotation direction without
changing the wiring to the encoder.
Ratio between motor speed and en-
coder speed. Remark: Only used when
gear mounted.
The feedback can be with or without
direction information. For TTL/HTL en-
coder, direction info is available. For
proximity switch, select [1] Without Di-
rection Info.
Frequency of the feedback filter. De-
fault value is 200 Hz (off) if the encoder
resolution is higher than 150 PPR. A fil-
ter value of 200 Hz is selected, mean-
ing that the filter is off. The use of fil-
ters depends on the given encoder res-
olution, gear ratio, and feedback type.
Time period where the option is al-
lowed to be below 120 RPM when SLS
is active before STO is activated.
AQ279747441421en-000101 / 130R0292 | 63
General Parameter Set-up
Con-
Data
ver-
type
sion
index
1
u_int8
0
u_int16
u_int8
-4
u_int32
u_int9
-2
u_int16
74
u_int16
67
u_int16

Hide quick links: