Danfoss VLT Safety Option MCB 150 Installation Manual page 62

Hide thumbs Also See for VLT Safety Option MCB 150:
Table of Contents

Advertisement

Installation Guide | VLT® Safety Option MCB 150/151
Bit number
Bit name
20
Suspension of speed monitoring
21
Power Up Self-Test warning
22
Digital input 1 offline test warning
23
Digital input 2 offline test warning
24–31
Causes for possible internal or external errors. See error code.
Parameter 42-81 Safe Option Status 2 indicates which digital input of the safety option is either activated, in pending state, or in
blank initial state.
Table 12: Explanation of the Status Bits for Safety Option Status 2
Bit
Description
0
DI1 safety status
1
2
DI 2 safety status
3
4
Blank initial state
5
Unused
31
Table 13: Bit Functions, Status 2
But number
Bit name
00-01
DI1 safety status
02-03
DI2 safety status
62 | Danfoss A/S © 2018.09
Value
Function
0
No change in state.
1
Suspension of speed monitoring - see error code.
0
No change in state.
1
Power Up Self-Test warning is issued.
0
No change in state.
1
Digital input 1 offline test warning.
0
No change in state.
1
Digital input 2 offline test warning.
N O T I C E
State
00 - Inactive
01 - Active
10 - Pending
00 - Inactive
01 - Active
10 - Pending
0 (inactive/1 (active)
Value
Function
00
Inactive
01
Active
10
Pending
00
Inactive
01
Active
10
Pending
General Parameter Set-up
AQ279747441421en-000101 / 130R0292