Mating connectors:
Molex Mini-Fit-Jr
receptacle p/n
J1 39-01-2140
J2 39-01-2040
J3 39-01-2020
with appropriate
45750-series
crimp terminals.
Curtis 1220 Manual,
Rev. C
CONNECTIONS: High Current
Four 1/4" Faston terminals are provided for the high current connections.
The motor connections (
B+
B-
connections (
,
) have one terminal each.
CONNECTIONS Low Current
The low current connections are made through three connectors: J1, J2, and J3.
1
2
3
8
9
10
J1
14-pin Molex
39-28-8140
J2
4-pin Molex
39-28-8040
J3
2-pin Molex
39-28-8020
2 — INSTALLATION & WIRING:
M1
M2
,
) and battery
J1
4
5
6
7
11
12
13
14
1
Status LED
2
Steer Motor Encoder Phase A
3
Position Analog 2
4
Interlock Input
5
KSI
6
Command Analog 1
7
+5V
8
Rx2 (from traction controller)
9
Steer Motor Encoder Phase B
10
Feedback Pot Low
11
Position Analog 1
12
Steering Angle Output
13
Command Analog 2
14
Command Pot Low
1
Rx1 (from programmer)
2
GND
3
Tx1 (to programmer / 840)
4
B+
1
Fault Output
2
Home Switch

High Current Connections

M1
M2
B-
B+
J2
J3
1
2
1
3
4
2
5

Hide quick links: