General Information on the operating instructions These operating instructions offer important notes on handling of the dis- tance measuring devices DL100 of SICK AG. A prerequisite for safe work is compliance with all indicated safety notes and instructions. Furthermore, the local work safety regulations and general safety provi- sions applicable for the application of the distance measuring device must be complied with.
Distance measurement is performed by a reflector. SICK AG assumes no liability for direct or indirect loss or damage resulting from use of the product. This in particular applies for any differing use of the product that does not meet the intended purpose and that is not described or mentioned in this documentation.
Operating instructions Distance measuring device DL100 – PROFINET IO Safety Warning at the device The distance measuring device DL100 has a category 2 laser installed. The measuring device is marked with a warning. EN/IEC 60825-1:2014 Complies with 21CFR1040.10 and 1040.11 except for deviations Complies with 21 CFR 1040.10...
For measurement, either the reflector or the measuring device may move linearly along the laser beam. The distance measuring device DL100 is equipped with two Ethernet interfaces. They serve communication via PROFINET IO and diagnosis and parameterization via SOPAS ET. The two interfaces have equal priorities and are internally connected to one switch.
Page 36
NOTE! → Ready-made cables, see page 109, chapter 15.2. All electrical connections of the distance measuring device DL100 are M12 round plugs. The connection plugs of the distance measuring device are compatible to the SpeedCon™-quick connections and standard-M12 screw connections.
Operation via Ethernet (Ethernet interface) Operation via Ethernet (Ethernet interface) The distance measuring device DL100 is equipped with two Ethernet interfaces. They serve communication via PROFINET IO and diagnosis and parameterization via SOPAS ET. The two interfaces have equal priorities and are internally connected to one switch.
FFurthermore, the functions of auto negotiation, auto cross over and full duplex are implemented. The DL100 has an integrated dual port switch and can be used in star or line topology. The following functions are sup- ported by the device amongst others: Media Redundancy (MRP), Topology Detection (LLDP), Device Replacement with out exchangeable medium/PG function and MIB/SNMP.
Operating instructions Distance measuring device DL100 – PROFINET IO PROFINET IO-interface 10.1.3 Configure participants Each PROFINET IO filed device has its own MAC address. The MAC MAC-Adresse address of the DL100 PROFINET IO is written on the type label (e.g. 00:06:77:02:00:A7 → See page 18, chapter 3.1 „Type label”. Name, IP address assigned Additionally, a PROFINET IO field device requires a unique, plant-specific automatically device name.