3. Installation Method

Cautions on installation

Use the unit in the environment for the general specifications described in the manual.
Never use the unit in a place with dust, soot, conductive dust, corrosive gas or flammable gas,
a place exposed to high temperature, dew condensation or rain and wind or a place exposed
to vibration or impact.
If the unit is used in such a place, electrical shock, fire, malfunction, damage in the product or
deterioration of the product may be caused.
Never drop cutting chips or electric wire chips into the ventilation window of the FX
while drilling screw holes or wiring cables.
Such chips may cause fire, failure or malfunction.
After finishing installation, remove a dust preventing sheet adhered on the ventilation window
of the PLC and the FX
If the sheet remains attached, fire, failure or malfunction may be caused.
Securely connect connection cables such as extension cables and memory cassettes to specified
connectors.
Imperfect contact may cause malfunction.
The FX
-2LC can be installed on the right side of an FX
2N
extension unit.
The FX
-2LC can be attached with a DIN rail DIN46277 (width: 35 mm) or directly attached to a panel
2N
surface with screws (M4).
3.1 Installation on DIN rail
Align the upper side of the DIN rail mounting groove of the FX
mm) (
), and push it on the DIN rail.(
When removing the FX
rail.(
)
When attached to DIN rail

3.2 Direct installation on panel surface
Screw-tighten the FX
holes provided on the left side of the FX
Assure the interval of 1 to 2 mm between a unit or block installed on the left side of the FX

4. Connection to PLC Main Unit

Connect the FX
-2LC to the PLC main unit with an extension cable.
2N
FX
-2LC units are treated as special units of the PLC, and the special unit No. 0 to 7 is automatically
2N
assigned to each FX
FROM/TO instructions.)
One FX
-2LC unit occupies eight I/O points in the PLC main unit.
2N
For the details of I/O assignment in the PLC, refer to the manual of the PLC main unit.
FX
-32MR
2N
(X000 to X017)
COM
L
N
24+
X1
FX
2N
Y2
Y4
Y1
Y3
Y5
(Y000 to Y017)
Please check power supply specifications to decide the number of FX
to the FX
/FX
1N
2N
To connect the FX
For extension, an extension cable FX
required. Only one FX
( ) indicates the I/O No.
-2LC.
2N
)
-2LC, pull out downward the DIN rail mounting hook.(
2N
-2LC with M4 screws to a panel surface using two (upper and lower) mounting
2N
2N
-2LC unit from the one nearest to the PLC main unit. (These unit Nos. are used in
2N
FX
-4AD
2N
X2
X4
X10
X14
X16
X3
X7
X13
X15
POWER
0
1
2
3
4
5
6
7
IN
10
11
12 13
14
15
16
17
POWER
RUN
BATT.V
PROG.E
0
1
2
3
4
5
6
7
-32MR
OUT
CPU.E
FX
-4AD
10
11
12 13
14
15
16
17
2N
Y6
Y10
Y12
Y14
COM3
Y11
Y13
Y15
Special block
No. 0
/FX
/FX
extension unit and PLC.
2NC
3U
-2LC unit to the FX
2N
0N
-65EC can be used in one system.
0N
/FX
1N
2N
When removed from DIN rail
-2LC.
FX
-2LC
2N
POWER
FX
-2LC
2N
24V
24V
OUT1
A/D
OUT2
Special block
No. 1
Series PLC, the interface FX
2NC
-65EC (650 mm) and the FX
/FX
/FX
Series PLC main unit or
2N
2NC
3U
-2LC with a DIN rail DIN46277 (width: 35
), and remove from DIN
ƒ
FX
-32ER
2N
(X020 to X037)
COM
X0
X2
X4
X6
X0
X2
X4
X6
L
N
24+
X1
X3
X5
X7
X1
X3
X5
X7
0
1
2
3
4
5
6
7
IN
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
FX
-32ER
OUT
2N
0
1
2
3
4
5
6
7
Y0
Y2
Y4
Y6
Y0
Y2
Y4
Y6
COM1
Y1
Y3
COM2
Y5
Y7
COM3
Y1
Y3
COM4
Y5
Y7
Special block
(Y020 to Y037)
-2LC units that can be connected
2N
-CNV-IF is required.
2NC
-CNV-BC sold separately are
2N
-2LC
2N
-2LC.
2N
FX
-2LC
2N
POWER
POWER
FX
-2LC
2N
24V
OUT1
OUT2
No.2

Advertisement

Table of Contents
loading

Table of Contents