FX
-2LC SPECIAL FUNCTION BLOCK
2N
Cautions on Safety
(Make sure to read this paragraph before using the unit.)
Thoroughly read this manual, a separate USER'S MANUAL and all attached documents of the connected
programmable controller (hereafter referred to as "PLC") and other related units before starting installation,
operation and inspection/maintenance of the temperature control block. Acquire the knowledge on
equipment, the information on safety and all cautions before using the temperature control block.
In this instruction manual, cautions on safety are classified as "DANGER" or "CAUTION".
This symbol indicates that incorrect handling may generate a dangerous situation which may lead
to death or serious injury.
This symbol indicates that incorrect handling may generate a dangerous situation which may lead
to medium or minor injury or physical damage.
Even an item classified as "CAUTION" may lead to a severe result depending on the situation.
Each item describes important information. Make sure to observe each item marked with "DANGER" or
"CAUTION".
Carefully store the instruction manual offered together with the temperature control block so that the
operator can refer to it at any time necessary. Make sure to deliver the instruction manual to the end user.
We appreciate it very much that you have purchased the temperature control block FX
programmable controller.
This manual describes handling of the MELSEC-F Series Temperature Control Block FX
Thoroughly read this manual and other manuals of related products, and sufficiently understand the
specifications before use.
Make sure to deliver this manual to the end user.
Brand and product names described by/in this manual are trademarks or registered trademark of the
irrespective ownes.
Related Manuals
When you using the FX
-2LC for the first time, a separate FX
2N
Make sure to obtain the USER'S MANUAL from the dealer from which you have purchased the FX
2LC, and safely use the FX
-2LC.
2N
Supplied with
Manual name
Manual No.
product or
separately supplied
FX
-2LC
2N
JY992D85601
Additional Manual
USER'S MANUAL
FX
2N
JY992D66301 Supplied with product
HARDWARE MANUAL
FX
2NC
JY992D76401 Supplied with product
HARDWARE MANUAL
FX
Series
3U
JY997D18801 Supplied with product
HARDWARE MANUAL
FX
Series
3U
User's Manual
JY997D16501
Additional Manual
- Hardware Edition
FX SERIES
PROGRAMMING
JY992D88101
Additional Manual
MANUAL ΙΙ
FX
/FX
Series
3U
3UC
Programming Manual
JY997D16601
Additional Manual
- Basic & Applied
Instruction Edition
If necessary, obtain them from the dealer from which you have purchased the FX
1. Outline of Product
Cautions on design
Install a safety circuit outside the PLC so that the entire system conservatively operates even if
an abnormality occurs in the external power supply or a failure occurs in the PLC.
If the safety circuit is installed inside the PLC, malfunction and erroneous output may cause
USER'S GUIDE
accidents.
Make sure to construct an emergency stop circuit, protection circuit, interlock circuit to prevent
damage to a machine or instrument outside the PLC.
JY992D85601C
When the PLC or FX
value error by the self-diagnosis circuit, and all outputs turn off. When an abnormality occurs in
the I/O control area which cannot be detected by the CPU in the PLC, output control may be
disabled.
Design external circuits and the structure so that the entire system conservatively operates in
such cases.
When a failure occurs in a relay, transistor, triac, etc. in the FX
outputs may keep ON or OFF.
For output signals which may lead to severe accidents, design external circuits and the struc-
ture so that the entire system conservatively operates.
Caution on disposal
When disposing of the unit, treat it as industrial waste.
The temperature control block FX
equipped with two temperature input points and two transistor (open collector) output points is a special
block to control outputs of temperature inputs from thermocouples and platinum resistance thermometer
bulbs by PID control.
Connect the FX
2N
1) As input sensors, two thermocouples, two platinum resistance thermometer bulbs or one thermocouple
and one platinum resistance thermometer bulb are available.
2) Data can be read and written using FROM/TO instructions when the FX
FX
/FX
/FX
1N
2N
-2LC for Mitsubishi
2N
(The FX
-2LC performs arithmetic operation for PID control and output control. The PLC does not
2N
have to perform such control.)
-2LC.
2N
3) Disconnection of heaters can be detected by current detection.
4) The proportional band, the integral time and the derivative time can be easily set by auto tuning.
5) Channels are isolated from each other.
2. Outside Dimension
-2LC USER'S MANUAL is required.
2N
-
2N
Extension
cable
Description
Describes the specification, wiring,
installation of FX
-2LC.
2N
Describes the specification, wiring
FX -2LC
and installation of FX
series PLC.
2N
Describes the specification, wiring
and installation of FX
series PLC.
2NC
Describes the specification, wiring
and installation of FX
series PLC.
3U
Mounting hole 2-Φ4.5
Describes the specification, wiring
and installation of FX
series PLC.
3U
Describes the instructions of FX
/
1S
FX
/FX
/FX
series PLC.
1N
2N
2NC
This manual explains the installations
of FX
/FX
series PLC.
3U
3UC
-2LC.
2N
-2LC detects an abnormality such as a watch dog timer error or input
2N
-2LC or output unit of PLC,
2N
-2LC (hereafter referred to as "temperature control block" or "FX
2N
-2LC to the FX
/FX
/FX
/FX
Series PLC.
1N
2N
2NC
3U
2N
/FX
Series PLC.
2NC
3U
Connector for next
step extension cable
4(0.16)
POWER
DIN rail
(width: 35 mm)
mounting groove
2N
24V
OUT1
OUT2
87(3.43)
55(2.17)
Status indicator LED
DIN rail mounting hook
Unit : mm (inch)
Mass: 0.3kg
Terminal screws M3 (0.12)
3. Installation Method
Cautions on installation
Use the unit in the environment for the general specifications described in the manual.
Never use the unit in a place with dust, soot, conductive dust, corrosive gas or flammable gas,
a place exposed to high temperature, dew condensation or rain and wind or a place exposed
to vibration or impact.
If the unit is used in such a place, electrical shock, fire, malfunction, damage in the product or
deterioration of the product may be caused.
Never drop cutting chips or electric wire chips into the ventilation window of the FX
while drilling screw holes or wiring cables.
Such chips may cause fire, failure or malfunction.
After finishing installation, remove a dust preventing sheet adhered on the ventilation window
of the PLC and the FX
If the sheet remains attached, fire, failure or malfunction may be caused.
Securely connect connection cables such as extension cables and memory cassettes to specified
connectors.
Imperfect contact may cause malfunction.
The FX
-2LC can be installed on the right side of an FX
2N
extension unit.
The FX
-2LC can be attached with a DIN rail DIN46277 (width: 35 mm) or directly attached to a panel
2N
surface with screws (M4).
3.1 Installation on DIN rail
-2LC")
2N
Align the upper side of the DIN rail mounting groove of the FX
mm) (
), and push it on the DIN rail.(
When removing the FX
-2LC, pull out downward the DIN rail mounting hook.(
2N
rail.(
)
When attached to DIN rail
-2LC is connected to the

3.2 Direct installation on panel surface
Screw-tighten the FX
-2LC with M4 screws to a panel surface using two (upper and lower) mounting
2N
holes provided on the left side of the FX
Assure the interval of 1 to 2 mm between a unit or block installed on the left side of the FX
4. Connection to PLC Main Unit
Connect the FX
-2LC to the PLC main unit with an extension cable.
2N
Terminal block
FX
-2LC units are treated as special units of the PLC, and the special unit No. 0 to 7 is automatically
2N
assigned to each FX
-2LC unit from the one nearest to the PLC main unit. (These unit Nos. are used in
2N
FROM/TO instructions.)
One FX
-2LC unit occupies eight I/O points in the PLC main unit.
2N
For the details of I/O assignment in the PLC, refer to the manual of the PLC main unit.
FX
-32MR
2N
(X000 to X017)
COM
X2
X4
X10
X14
X16
L
N
24+
X1
X3
X7
X13
X15
0
1
2
3
4
5
6
7
IN
10
11
12 13
14
15
16
17
FX
-32MR
0
1
2
3
4
5
6
7
2N
OUT
10
11
12 13
14
15
16
17
Y2
Y4
Y6
Y10
Y12
Y14
Y1
Y3
Y5
COM3
Y11
Y13
Y15
(Y000 to Y017)
Please check power supply specifications to decide the number of FX
to the FX
/FX
/FX
/FX
1N
2N
2NC
3U
To connect the FX
-2LC unit to the FX
2N
For extension, an extension cable FX
required. Only one FX
-65EC can be used in one system.
0N
( ) indicates the I/O No.
-2LC.
2N
/FX
/FX
/FX
Series PLC main unit or
1N
2N
2NC
3U
-2LC with a DIN rail DIN46277 (width: 35
2N
)
), and remove from DIN
When removed from DIN rail
ƒ
-2LC.
2N
-2LC.
2N
FX
-2LC
FX
-32ER
2N
2N
(X020 to X037)
FX
-4AD
FX
-2LC
2N
2N
COM
X0
X2
X4
X6
X0
X2
X4
X6
L
N
24+
X1
X3
X5
X7
X1
X3
X5
X7
POWER
POWER
0
1
2
3
4
5
6
7
POWER
IN
0
1
2
3
4
5
6
7
POWER
POWER
RUN
BATT.V
PROG.E
FX
-2LC
FX
-32ER
OUT
0
1
2
3
4
5
6
7
FX
-2LC
CPU.E
FX
-4AD
2N
2N
2N
2N
0
1
2
3
4
5
6
7
Y0
Y2
Y4
Y6
Y0
Y2
Y4
Y6
COM1
Y1
Y3
COM2
Y5
Y7
COM3
Y1
Y3
COM4
Y5
Y7
24V
24V
OUT1
A/D
OUT2
Special block
Special block
Special block
(Y020 to Y037)
No. 0
No. 1
No.2
-2LC units that can be connected
2N
extension unit and PLC.
Series PLC, the interface FX
-CNV-IF is required.
2NC
2NC
-65EC (650 mm) and the FX
-CNV-BC sold separately are
0N
2N
-2LC
2N
24V
OUT1
OUT2

Advertisement

Table of Contents
loading

Table of Contents