Brush (Conductimethc Sensor); Rear Brush; Rear Air Duct With Fan - Electrolux EDR 2000 Service Manual

Heat pump dryer
Hide thumbs Also See for EDR 2000:
Table of Contents

Advertisement

7.15 Carbon brush
(conductivity sensor/monitor)
The lower carbon brush (1) monitors the conductivity at the contact band of the drum. The carbon with holder is
seated in a receptacle in the slot section.
The unit can be disengaged and removed by pressing the two clips (2).
1

7.16 Rear brush

(conductirnetric sensor)
Remove the screw which secures
the drum spindie cover.
Rotate the drum cover until it is
released from the anchor in the
lower section.
The brush is located inside the
protective cover.
7.17 Rear air channel with fan
After releasing all screws (1), the complete
rear air channel (2) with fan (6) can be
removed.
The electrical connection runs through the
corresponding connection openings (8)
over a plug connector.
After unscrewing the screws (7), the fan (6)
can be removed.
The channel itself consists of the exterior
covering (3), the isolation mat (4) and the
inner air channel (5).
3
06.2005 R.Kurzke
4
5
- 22 -
1
2
1
2
7
8
8
2
6
599 522 797 EN