GB
Symbol and function explanations
Inlet spatter removal air
Shielding gas
Outlet spatter removal air
Used for spray-cleaning the contact tip on the welding gun.
Gas purging
Used to measure the gas flow or to flush the gas hoses to clean them of any air and
moisture before commencing welding. Gas purging is carried out with the voltage
and wire feed switched off.
Inching
Used when wire is to be fed without switching on the welding voltage.
Shielding gas out
5.2

Replacing and inserting wire

S
Open the side panel.
S
Disconnect the pressure sensor by folding it backwards, the pressure rollers
slide up.
S
Straighten out the new wire 10-20 cm. File off any burrs and sharp edges from
the end of the wire before inserting it into the wire feed unit.
S
Make sure that the wire goes properly into the feed roller's track and into the
outflow nozzle or wire guide.
S
Secure the pressure sensor.
S
Close the side panel.
WARNING
Risk of crushing when replacing the wire bobbin!
Do not use safety gloves when inserting the welding wire between the feed rollers.
bm54d1ea