5   OPERATION
4) Locate the control wire assembly, align keyway with the key on the remote control socket, insert
plug, and rotate threaded collar fully clockwise.
1. Thumb screw
5.5

Inserting and replacing wire

Rogue EM 190 can be used with bobbin sizes of 4 in. (100 mm) and 8 in. (200 mm). See Section 3
"Technical data", page 11, for suitable wire dimensions for each wire type.
WARNING!
Do not place or point the torch near the face, hand, or body as this may result in personal
injury.
WARNING!
Make sure that the power is turned off, before replacing or installing any parts.
WARNING!
Risk of crushing when replacing the wire bobbin! Do not use safety gloves when inserting the
welding wire between the feed rollers.
1) Open the spool side door.
2) Release the pressure roller arm by levering the tension screw (1).
3) Lift the pressure roller arm (2).
4) With the GMAW welding wire feeding from the bottom of the spool, pass the electrode wire through
the inlet guide (3), between the rollers, through the outlet guide and into the GMAW torch. Ensure
that the wire is aligned with the correct groove in the drive roll.
0447 956 001
2. Torch receptacle
- 19 -