3. FUNCTION SETTINGS
<List of maintenance information>
Screen
1
2
3
4
33
Panel display
X-over sensor 1
・
Displays the X-over seam sensor adjustment value 1 (200 -
1400).
X-over sensor 2
・
Displays the X-over seam sensor adjustment value 2 (300 -
3400).
U-shaft REF position ADJ value
・
Displays the upper shaft reference position adjustment value
(60 - 100).
Feed REF position correction value
・
Displays the feed reference position correction value (-300 -
300).
Grease up counter(%)
・
For -[]3[] specifications, 0 - 102 is displayed.
(If the value is 100 or more, the grease up warning screen is
displayed when the power is turned on.)
For -[]0[] specifications, 0 is displayed.
Grease up time
・
For -[]3[] specifications, 4000 is displayed.
For -[]0[] specifications, 0 is displayed.
Accumulated power on time
・
Displays the accumulated power on time (x 1 sec).
Accumulated motor running time
・
Displays the accumulated motor running time for the sewing
machine (x 1 sec).
S-7300A
Display details