Brother S-7300A Service Manual page 183

Single needle direct drive lock stitcher with electronic feeding system and thread trimmer
Hide thumbs Also See for S-7300A:
Table of Contents

Advertisement

<Power switch>
Ground wire
1. Disconnect the power supply connector 3P (3) from the
control box.
2. Turn on the power switch.
3. Measure the voltage at the power supply connector (3)
using the AC voltage range of a multimeter, and check
that the voltage is within the allowable range for the
specified voltage rating.
If the value is as shown in the table below, the connector
is normal.
Between 2 - 3
1074D
S-7300A
10. ELECTRIC MECHANISM
AC 180V - 265V
172