Accessing Fryer For Servicing; Cleaning The Gas Valve Vent Tube; Checking The Burner Manifold Gas Pressure; Taking An Incoming Supply Gas Pressure Reading - Pitco SG Series Solstice Service Manual

High efficiency gas fryers
Hide thumbs Also See for SG Series:
Table of Contents

Advertisement

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers 
 
 
Accessing Fryer for Servicing 
1. Shut off the main gas supply line.
Cleaning the Gas Valve Vent Tube 
See "Cleaning the Gas Valve Vent Tube" on page 13.
Checking the Burner Manifold Gas Pressure 
Taking an Incoming Supply Gas Pressure Reading
1. Unscrew and remove the gas supply plug with a
3/16 inch hex wrench.
2. Finger tighten the test fitting into the test port.
3. Finish tightening the test fitting using a 7/16
inch open-ended wrench.
 
SG/SSH Series Service Manual 
2. Shut off the individual gas supply line.
4. Connect the manometer.
5. Turn on the main gas supply line.
51 