Solid State Thermostat Field Calibration - Pitco SG Series Solstice Service Manual

High efficiency gas fryers
Hide thumbs Also See for SG Series:
Table of Contents

Advertisement

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers 
 
 
Solid State Thermostat Field Calibration 
If field calibration is necessary, follow these steps:
Allow appliance to heat to set point, and allow 30 minutes to stabilize.
Measure the vat center oil temperature. Compare this with the knob pointer scale.
To reposition the knob, pry off the cap of the knob with a sharp knife blade.
Without turning the shaft, loosen the 5/16-compression nut and pull the knob off.
Re-install the knob with the pointer at the temperature indicated on the test thermometer.
Tighten the 5/16-compression nut, and install cap.
 
SG/SSH Series Service Manual 
79 