YASKAWA AO-A3 User & Installation Manual page 29

Ac drive option analog monitor
Hide thumbs Also See for AO-A3:
Table of Contents

Advertisement

Ferrule-Type Terminals
n
Yaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent ferrule-type
terminals with the specifications listed in
Note: Properly trim wire ends so loose wire ends do not extend from the crimp terminals.
Ferrule-Type
Terminal
6 mm
d2
d1
L
u
Terminal Functions
Terminal
V1
Analog voltage output 1
V2
Analog voltage output 2
AC
Common
FE
Ground
<1> Set the functions and output levels for terminals V1 and V2 using drive parameters. See the drive Instruction
Manual for directions on setting parameters.
YASKAWA ELECTRIC TOBP C730600 79C YASKAWA AC Drive Option AO-A3 Installation Manual
Table 4 Ferrule-Type Terminal Sizes
Wire Gauge
Phoenix Contact
mm
2
0.25 (24 AWG)
AI 0.25 - 6YE
0.34 (22 AWG)
AI 0.34 - 6TQ
0.5 (20 AWG)
AI 0.5 - 6WH
Table 5 Option Terminal Functions
Function
Signal Level
-10 to 10 V
Table 4
for wiring to ensure proper connections.
L
Model
mm (in)
10.5 (13/32)
10.5 (13/32)
14 (9/16)
• Analog voltage output for an external monitoring
device
<1>
• Output resolution 11-bit plus sign (1/2048)
• Max. load current 3 mA
0 V
Common for analog voltage output
Used for grounding shielded lines
5 Installation Procedure
d1
mm (in)
0.8 (1/32)
0.8 (1/32)
1.1 (3/64)
Description
d2
mm (in)
2 (5/64)
2 (5/64)
2.5 (3/32)
29