Fluke Thermalert 4.0 User Manual page 84

Smart integrated infrared sensors
Table of Contents

Advertisement

®
Thermalert
4.0 Series
Users Manual, Rev. 1.1, May 2018
COMMAND LIST
Description
Lower threshold value for
Relay function
Firmware revision
Analog Firmware revision
Upper threshold value for
Relay function
Trigger status
Device identification (model
name)
Device serial number
Advanced hold - hysteresis
temperature value
Amb count + IR ADC count
value
PSa value + Energy value
86
1.800.561.8187
Char
Value Format
Poll
Burst
XP
nnnn.n
XR
nn.nn.nnnn
XRA
nn.nn.nnnn
XS
nnnn.n
XT
n
XU
XXXXXXXXXXX
XV
nnnnnnnnn
XY
nnnn.n
YA
nnnnn#nnnnnn
YB
nnnnnn#nnnnnn
www.
Set
Legal values
Lower-limit of
temperature range ~
(Upper threshold value
for Relay function - 2 *
Deadband).
In current unit (°C/°F)
e.g. 01.01.1111
e.g. 01.01.1111
(Lower threshold value
for Relay function + 2 *
Deadband) ~ Upper-limit
of temperature range.
In current unit (°C/°F)
0 = inactive;
1 = active
e.g. STRLTH5SFCW
e.g. 123456789
-100.0 ~ 100.0oC / -
180.0 ~ 180.0oF
In current unit (°C/°F)
information@itm.com
.com
Factory
2-W
6-W
12-W
default
Lower-limit of
temperature
range
Upper-limit of
temperature
range
0
0000.0