Outputs and Ground
If you cut the cable to shorten it, notice that both sets of twisted-pair wires have drain wires inside their
insulation. These drain wires (and the white wire that is not part of the twisted pair) must be connected to the
If you purchase your own cable, use wire with the same specifications as herein mentioned. Maximum
RS485 cable length is 1.200 m (4000 ft). Power supply feed in distance to the Thermalert 4.0 sensor should
54
1.800.561.8187
6 wires (green/brown/blue/orange/yellow/clear)
Conductor:
0.2 mm² (AWG 24), tinned copper
Isolation:
PE- 2YI1
Shield:
none
Risk of Personal Injury
Polyurethane (Isocyanate) may cause allergy and possibly cancer!
An ordered cable does not include a terminal block!
www.
Note
Note
terminal labeled CLEAR.
Note
not extend the 60 m (200 ft) limit.