Fluke 80i-110s Instructions Manual

Fluke 80i-110s Instructions Manual

Ac/dc current probe
Hide thumbs Also See for 80i-110s:

Advertisement

Quick Links

Introduction
The Fluke 80i-110s (the Probe or Product) is a clamp-on AC/DC Current
Probe that reproduces current waveforms found in commercial and industrial
power distribution systems. The Probe performance is optimized for accurate
reproduction of currents at line frequency and up to the 50
waveform. The 80i-110s is also compatible with any instrument capable of
millivolt measurements.
The Probe provides these benefits:
• Accurate AC, DC, and AC+DC current measurements for Electrical,
Electronic, and Automotive applications.
• Shielded for high-noise immunity around electronic motor drives and
ignition systems.
• Wide measurement range from 50 mA to 100 A, useful to 10 mA.
• Jaw shaped for easy access to cramped spaces.
• Tactile barrier (see Figure 1, item
• Safety-designed 600 V insuIated BNC - compatible with Fluke
®
ScopeMeter
oscilloscopes.
• Selectable output of 10 millivolts/1 amp for the 100 A range, and
100 mV/1 A for the 10 A range.
Figure 1. 80i-110s AC/DC Current Probe
PN 4862926 October 2005, Rev. 1, 1/17
©2005-2017 Fluke Corporation.
All rights reserved. Specifications are
subject to change without notification.
All product names are trademarks of their
respective companies.
AC/DC Current Probe
test tools, Power Harmonic analyzers, and
Instructions
).
1
80i-110s
th
harmonic

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 80i-110s

  • Page 1 AC/DC Current Probe Instructions Introduction The Fluke 80i-110s (the Probe or Product) is a clamp-on AC/DC Current Probe that reproduces current waveforms found in commercial and industrial power distribution systems. The Probe performance is optimized for accurate reproduction of currents at line frequency and up to the 50 harmonic waveform.
  • Page 2: How To Contact Fluke

    How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • Japan: +81-3-6714-3114 • Singapore: +65-6799-5566 • Anywhere in the world: +1-425-446-5500 To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals.
  • Page 3: Before You Start

    Before You Start These items are included in the shipment box: • AC/DC Current Probe, 80i-110s • Instructions (this document) • 9 volt Battery, type IEC 6LR61 Check the contents of the box for completeness. If something in the box is damaged or missing, contact your distributor or the nearest sales or service office.
  • Page 4 Battery Warning To prevent electrical shock, unclamp the Probe from any conductor, and disconnect the Scopemeter test tool or any other measurement device before you install or replace the battery. Before the first use, install the battery. See Figure 2. To install the battery: Unclamp the Probe from any conductor and disconnect the ScopeMeter test tool or any other measurement device.
  • Page 5 Compatibility The Product is compatible with any Fluke ScopeMeter test tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage measurement device with these features: • BNC input connector (PN PM9081/001 BNC-to-banana adapter) for use with standard inputs on a digital multimeter (DMM).
  • Page 6: Measurement Guidelines

    At completion, set the range selection switch to OFF again. A measurement setup with the Probe and a ScopeMeter test tool is shown in Figure 4. Figure 4. Measurement Setup Measurement Guidelines Use these guidelines to position the jaws: • Center the conductor inside the jaws. •...
  • Page 7: Cleaning And Storage

    Repairs or service not covered in this document must be performed only at a Fluke Service Center. A Probe under warranty will be repaired or replaced (at Fluke's discretion) and returned at no charge. Cleaning and Storage Periodically wipe the case with a damp cloth and detergent.
  • Page 8: Electrical Specifications

    Battery Type ......... 9 volt, IEC 6LR61 Consumption ......8.6 mA typical 12 mA maximum Service life with Alkaline IEC 6LR61 battery Typical......55 hours Minimum......40 hours Battery indicator (ON)....Green LED dims when battery voltage is <6.5 V Safety General........
  • Page 9: Performance Verification

    Make the checks called for in Table 3 (100 mV/A). Make the checks called for in Table 4 (10 mV/A). Table 1. Required Test Equipment Required Recommended AD/DC Calibrator Fluke 5520A Digital Multimeter (DMM) Fluke 45 Small insulated screwdriver Spectrol Banana-to-BNC Adapter...
  • Page 10 5520A Figure 5. Performance Test and Calibration Setup Table 2. Toroid Coil Construction   10.5 cm (4 in)  Item Description  10 turns wound on cylindrical form using 10-gauge magnet wire. Remove form and tape coil together making sure 10 wires are ...
  • Page 11 Table 3. Performance Test Points: Current Range 0 A to 10 A (100 mV/A) DC Measurement: 5520A DC Amps Low Limit High Limit Settings Measured Output Output 0.1 A 92 mV 108 mV 0.5 A 480 mV 520 mV 0.9 A 868 mV 932 mV AC Measurement:...
  • Page 12 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.