4. MULTIPLE REMOTE CONTROLLER ADAPTER
This adapter is needed for remote indication (operation/check). Adapter connection is described on page .
Part No.
1
2
3
4
5
5. CENTRALIZED REMOTE CONTROLLER
Allows individual or combined control of up to 16 units. When using the PAC-80RC, the program timer adapter (PAC-82AD)
is also needed. See page .
Part No.
5-1 Dimensions
POWER
E N G A G E D
ON/OFF
G R O U P
1 2 3 4 5 6 7 8 9 10
G R O U P
BACK
AHEAD
S E L E C T I O N
P R O G R A M
ACTIVE
A C T I V E B Y P A S S
T I M E R
BYPASS
C O N T R O L L E R
DUAL
D U A L C E N T R A L
O P E R A T I O N
CENTRAL
MITSUBISHI ELECTRIC
1 1 7
5-2 Functions
"ENGAGED" indicator
When this indicator is lit, transmission is in
progress and all switches are inoperative.
DUAL/CENTRAL switch
This change-over switch governing the
operation of the accessory remote control-
ler.
"DUAL"
Instructions from both the accessory
remote controller and the centralized
remote controller are valid. (Priority given
to the last instruction received.)
"CENTRAL"
ON/OFF switching by the accessory
remote controller is invalidated. Control is
by the centralized remote controller only.
Initial setting is "DUAL".
LCD Matrix Display
This display indicates the operational sta-
tus of all connected units either by steady
lighting or by flashing.
Independent "DUAL / CENTRAL" and "ACTIVE / BYPASS" setting of all the groups is possible. When the power supply to the
centralized remote controller is cut due to power failure, all settings will return to original "DUAL" and "BYPASS".
OC229A
PAC-SA88HA-E
BRN
RED
ORN
YLW
GRN
PAC-80RC
1 2
E N G A G E D
G R O U P
1 2 3 4 5 6 7 8 9 10
A C T I V E B Y PA S S
D U A L C E N T R A L
6
6
1 1 3
5 6 . 3
1 1
2 3 . 5
POWER
E N G A G E D
ON/OFF
G R O U P
1 2 3 4 5 6 7 8 9 10
G R O U P
BACK
AHEAD
S E L E C T I O N
P R O G R A M
ACTIVE
A C T I V E B Y P A S S
T I M E R
BYPASS
C O N T R O L L E R
DUAL
D U A L C E N T R A L
O P E R A T I O N
CENTRAL
10 9 8 7 6 5 4 3 2 1
POWER ON/OFF switch
Operation ON/OFF switch.
▲BACK
These buttons are used to designate
the attached unit(s). (They designate
the unit that is centrally controlled.)
POWER
ON/OFF
● When group "00" is designated; col-
G R O U P
AHEAD
BACK
S E L E C T I O N
P R O G R A M
ACTIVE
T I M E R
BYPASS
● When group "01"-"16" is designated;
C O N T R O L L E R
DUAL
O P E R AT I O N
CENTRAL
MITSUBISHI ELECTRIC
ACTIVE/BYPASS switch
This is a change-over switch for the
program timer.
(It selects timer operation on the pro-
gram timer.)
Use "BYPASS" when a program timer
is not connected.
"ACTIVE"
The switch turns ON/OFF operational
instructions from the program timer
automatically.
"BYPASS"
ON/OFF Operation is by the central-
ized remote controller only.
Initial setting is "BYPASS".
Unit : mm
▼AHEAD buttons
lective ON/OFF instruction is sent to
all units.
ON/OFF instruction is sent to the
designated units only.