Mitsubishi PKH-1.6GKLH Technical & Service Manual page 20

Pkh series. wall mounted
Table of Contents

Advertisement

DRY OPERATION
Vane
setting notch
w8~9 Refer to page 26~27.
w12
When room temperature is 18°C or below, the compressor cannot operate.
When room temperature rises over 18°C, the compressor starts after a -minute time delay.
w1
Compressor ON time is decided by room temperature. Refer to page 26~27.
w1
In dry operation, compressor ON makes the fan speed LOW. Also, when the compressor OFF and the pipe tempera-
ture is 26°C or less, the fan stops, or when the compressor OFF and the pipe temperature is below 6°C, the fan speed
changes to LOW mode.
It is not possible to set the fan speed with the remote controller
OC229A
DRY
operation
Four-way valve / OFF
NO
Initial dry
operation
YES
Vane initial setting
YES
Room temperature is
18°C or lower
NO
During
compressor ON
YES
-minute
compressor
operation
YES
NO
Compressor &
thermostat ON
YES
Compressor ON
time completes
YES
10-minute compressor
OFF timer start
Compressor OFF
Fan STOP
1
w8
w12
NO
NO
w9
YES
NO
w1
20
YES
-minute
time delay
NO
w9
Compressor &
thermostat
ON
NO
10-minute
NO
compressor
OFF
YES
w1
Compressor ON
time set
Compressor ON
w1
Fan speed LOW