Mitsubishi Mr.Slim PCH-3GAK Brochure & Specs

Mitsubishi Mr.Slim PCH-3GAK Brochure & Specs

Mitsubishi electric split-type air conditioners brochure

Advertisement

SPLIT-TYPE AIR CONDITIONERS
Natural Comfort
For
Everybody
POWER CEILING CASSETTE
R22
WALL MOUNTED
CEILING SUSPENDED
CEILING CONCEALED

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Mr.Slim PCH-3GAK

  • Page 1 SPLIT-TYPE AIR CONDITIONERS Natural Comfort Everybody POWER CEILING CASSETTE WALL MOUNTED CEILING SUSPENDED CEILING CONCEALED...
  • Page 2: Outdoor Unit

    P R O D U C T L I N E - U P PLH-3AAK PLH-AAK Power ceiling cassette PKH-3FAK PKH-FAK Wall mounted PCH-3GAK PCH-GAK Ceiling suspended PEH-2.5EAK PEH-3EAK PEH-EAK Ceiling concealed OUTDOOR UNIT PUH-2.5AKA PUH-3VKA*/PUH-3YKA *PUH-3VKA is only for PEH series.
  • Page 3: Table Of Contents

    PLH-4AAK PLH-5AAK PKH-4FAK PCH-4GAK PCH-5GAK PEH-4EAK PEH-5EAK PUH-4YKSA PUH-5YKSA PLH-6AAK PCH-6GAK PEH-6EAK PUH-6YKSA Remote controller Contents Optional P.10...
  • Page 4 High performance, low power consumption, In today’s competitive environment, simply meeting industry standards, however stringent, is not enough. Our aim is to exceed them. That’s why when it comes to comfort, efficiency and durability: Mitsubishi Electric offers you a distinctive advantage. We call it MEQ —...
  • Page 5 Renovating air conditioning communication by advanced MA Remote Controller newly developed Dot Liquid Crystal Display Acknowledging the operation and control status at a glance. The large size display upgrades visual acknowledgement capability. The operation and control status can be understood promptly.
  • Page 6 Mr. SLIM New A/K Control System Configuration Control function System configuration Group control Remote with 1 remote Controller controller Combined Remote/local Distant Controller control Panel Operation with 2 remote Remote Controller controllers Individual control from Remote distant room Controller 5. Timer operation Operation by external signal...
  • Page 7: Wired Remote Controller

    Used to select operating modes — Cool, Dry, and Heat, and Auto. ● TIMER CONTROL buttons STOP (OFF timer): activated, the air conditioner will auto- matically stop at the preset time. START (ON timer): activated, the air conditioner will auto- matically start at the preset time.
  • Page 8: Plh-4Aak

    Automatic vane shutter When the air conditioner is not operat- ing, the vane shutter* closes automati- cally to conceal the air outlet and create an aesthetically appealing flat surface. * This feature will not activate when the vane is set at fixed position.
  • Page 9: Pkh-4Fak

    W A L L M O U N T E D PKH-FAK S E R I E S PKH-3FAK PKH-4FAK INDEX Specifications ...p.11 Option ...p.13 Auto-flap shutter When the unit is turned off, the shutter closes automatically over the air outlet to enhance the stylish design.
  • Page 10: Pch-4Gak

    C E I L I N G S U S P E N D E D PCH-GAK S E R I E S PCH-3GAK PCH-4GAK PCH-5GAK PCH-6GAK INDEX Specifications ...p.12 Option ...p.13 Extra slim, extra stylish Sleek and slim with stylishly curved lines, the PCH-GAK Series blends right into any interior.
  • Page 11: Peh-4Eak

    C E I L I N G C O N C E A L E D PEH-EAK S E R I E S PEH-2.5EAK PEH-3EAK PEH-4EAK PEH-5EAK PEH-6EAK PEH-2.5EAK PEH-3EAK PEH-4EAK PEH-5EAK PEH-6EAK INDEX Specifications ...p.12 Option ...p.13 Limitless installation possibilities Offering all the benefits of split-type models plus other important advantages, the PEH-EAK Series is not only easy to install but also very versatile.
  • Page 12: Puh-5Yksa

    S P E C I F I C A T I O N S PLH-AAK POWER CEILING CASSETTE Models Function Capacity Total input Model name External finish Power supply Airflow ( Lo-Hi) External static pressure Pa ( mmAq) Indoor unit Sound pressure level ( Lo-Hi) W mm Dimensions...
  • Page 13: Ceiling Suspended

    S P E C I F I C A T I O N S PCH-GAK CEILING SUSPENDED i t c y t i e t x n i f h s i y l p l f r i ) i H s / l r e t c i t...
  • Page 14: Refrigerant Piping

    G E N E R A L S P E C I F I C A C I O N S F O R A L L M O D E L S ■ Notes for All Specifications ● Rating conditions: Cooling - Indoor 27ºCDB, 19ºCWB; Outdoor 35ºCDB Heating - Indoor 20ºCDB ;...
  • Page 15: Outdoor Unit Installation Location

    ■ The remote-control circuits under microprocessor control remain on at all times whether the air conditioner is or is not in operation. For more economical operation, it is recommended that the main power switch be turned off when the air conditioner(s) is not used for long periods.
  • Page 16 Mitsubishi Electric Shizuoka Works acquired ISO 9001 certification under Series 9000 of the International Standard Organization (ISO) based on NATIONAL ACCREDITATION OF CERTIFICATION ISO 9001 BOOIS a review of Quality warranties for the production of Certificate Number 49385 refrigeration and air conditioning equipment. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN MITSUBISHI ELECTRIC AUSTRALIA PTY LTD.

Table of Contents